Development in anterior segment imaging for glaucoma
Abstract
Purpose of review: Recent developments in anterior segment imaging enable high-resolution imaging with higher speeds than previous systems. This review will focus on advances in optical coherence tomography (OCT) imaging of the anterior segment with an emphasis on angle evaluation.
Recent findings: Anterior segment imaging with OCT is possible with both time domain and Fourier domain devices, and with light sources of different wavelengths. Recent studies have identified new risk factors for angle closure and prediction models incorporating quantitative angle width parameters have been developed for detection of gonioscopically defined angle closure. Swept source OCT is a variation of Fourier domain OCT that allows three-dimensional imaging of the angle analogous to gonioscopy and novel quantitative parameters have been described for angle measurement with this technology. Fourier domain OCT devices have higher resolution and sampling density than time domain OCT and enable visualization of more angle structures such as the Schwalbe's line and Schlemm's canal.
Summary: OCT technology is expanding our understanding of angle closure disease. Although it does not replace gonioscopy in angle evaluation, it may help us identify predictors of progression along the angle closure disease spectrum such that treatment may be better targeted.
Similar articles
-
Comparison of two spectral domain optical coherence tomography devices for angle-closure assessment.Invest Ophthalmol Vis Sci. 2012 Aug 3;53(9):5131-6. doi: 10.1167/iovs.12-10132. Invest Ophthalmol Vis Sci. 2012. PMID: 22786910
-
Detection of primary angle closure using anterior segment optical coherence tomography in Asian eyes.Ophthalmology. 2007 Jan;114(1):33-9. doi: 10.1016/j.ophtha.2006.05.073. Epub 2006 Oct 27. Ophthalmology. 2007. PMID: 17070597
-
Comparison of spectral domain and swept source optical coherence tomography for angle assessment of Chinese elderly subjects.BMC Ophthalmol. 2019 Jul 8;19(1):142. doi: 10.1186/s12886-019-1145-7. BMC Ophthalmol. 2019. PMID: 31286869 Free PMC article.
-
Application of anterior segment optical coherence tomography in glaucoma.Surv Ophthalmol. 2014 May-Jun;59(3):311-27. doi: 10.1016/j.survophthal.2013.06.005. Epub 2013 Oct 15. Surv Ophthalmol. 2014. PMID: 24138894 Review.
-
Role of anterior segment optical coherence tomography in angle-closure disease: a review.Clin Exp Ophthalmol. 2018 Mar;46(2):147-157. doi: 10.1111/ceo.13120. Epub 2017 Dec 28. Clin Exp Ophthalmol. 2018. PMID: 29193702 Review.
Cited by
-
Corneal higher-order aberrations in corneal endothelial decompensation secondary to obstetric forceps injury.Sci Rep. 2023 Apr 3;13(1):5389. doi: 10.1038/s41598-023-32683-5. Sci Rep. 2023. PMID: 37012353 Free PMC article.
-
Corneal Higher Order Aberrations in Granular, Lattice and Macular Corneal Dystrophies.PLoS One. 2016 Aug 18;11(8):e0161075. doi: 10.1371/journal.pone.0161075. eCollection 2016. PLoS One. 2016. PMID: 27536778 Free PMC article.
-
Hand-held optical coherence tomography imaging in children with anterior segment dysgenesis.Acta Ophthalmol. 2017 Aug;95(5):537-541. doi: 10.1111/aos.13053. Epub 2016 Apr 30. Acta Ophthalmol. 2017. PMID: 27130748 Free PMC article. No abstract available.
-
Large Amplitude Iris Fluttering Detected by Consecutive Anterior Segment Optical Coherence Tomography Images in Eyes with Intrascleral Fixation of an Intraocular Lens.J Clin Med. 2022 Aug 6;11(15):4596. doi: 10.3390/jcm11154596. J Clin Med. 2022. PMID: 35956211 Free PMC article.
-
Assessment of the anterior segment of patients with primary congenital glaucoma using handheld optical coherence tomography.Eye (Lond). 2019 Aug;33(8):1232-1239. doi: 10.1038/s41433-019-0369-3. Epub 2019 Mar 18. Eye (Lond). 2019. PMID: 30886322 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Research Materials