Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2014 Apr;58(2):214-22.
doi: 10.1111/1754-9485.12145. Epub 2013 Dec 25.

SPECT-based functional lung imaging for the prediction of radiation pneumonitis: a clinical and dosimetric correlation

Affiliations

SPECT-based functional lung imaging for the prediction of radiation pneumonitis: a clinical and dosimetric correlation

Douglas A Hoover et al. J Med Imaging Radiat Oncol. 2014 Apr.

Abstract

Introduction: When we irradiate lung cancer, the radiation dose that can be delivered safely is limited by the risk of radiation pneumonitis (RP) in the surrounding normal lung. This risk is dose-dependent and is commonly predicted using metrics such as the V20, which are usually formulated assuming homogeneous pulmonary function. Because in vivo pulmonary function is not homogeneous, if highly functioning lung can be identified beforehand and preferentially avoided during treatment, it might be possible to reduce the risk of RP, suggesting the utility of function-based prediction metrics.

Methods: We retrospectively identified 26 patients who received ventilation and perfusion single photon emission computed tomography (SPECT-CT) immediately prior to curative-intent radiation therapy. Patients were separated into non-RP and RP groups. As-treated dose-volume histogram (DVH), perfusion-SPECT-based and ventilation-SPECT-based dose-function histogram (DFH) parameters were defined for each group and were tested for differences. The relative utilities of ventilation-based and perfusion-based DFH metrics were assessed using receiver operating characteristic (ROC) analysis.

Results: The standard mean lung dose (MLD) was significantly higher in the RP group; the standard V20 and V30 were higher in the RP group but not significantly. Perfusion-weighted and ventilation-weighted values of the MLD, V20 and V30 were all significantly higher in the RP group. ROC analysis suggested that SPECT-based DFH parameters outperformed standard DVH parameters as predictors of RP.

Conclusions: SPECT-based DFH parameters appear to be useful as predictors of RP.

Keywords: DFH; SPECT; dose-function histogram; functional lung imaging; lung cancer.