Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2014 Aug;28(8):439-43.
doi: 10.1097/BOT.0000000000000059.

Computerized Adaptive Testing Using the PROMIS Physical Function Item Bank Reduces Test Burden With Less Ceiling Effects Compared With the Short Musculoskeletal Function Assessment in Orthopaedic Trauma Patients

Affiliations
Comparative Study

Computerized Adaptive Testing Using the PROMIS Physical Function Item Bank Reduces Test Burden With Less Ceiling Effects Compared With the Short Musculoskeletal Function Assessment in Orthopaedic Trauma Patients

Man Hung et al. J Orthop Trauma. 2014 Aug.

Abstract

Purpose: Patient-reported outcomes are important to assess effectiveness of clinical interventions. For orthopaedic trauma patients, the short Musculoskeletal Function Assessment (sMFA) is a commonly used questionnaire. Recently, the Patient-Reported Outcome Measurement Information System (PROMIS) PF Function Computer Adaptive Test (PF CAT) was developed using item response theory to efficiently administer questions from a calibrated bank of 124 PF questions using computerized adaptive testing. In this study, we compared the sMFA versus the PROMIS PF CAT for trauma patients.

Methods: Orthopaedic trauma patients completed the sMFA and the PROMIS PF CAT on a tablet wirelessly connected to the PROMIS Assessment Center. The time for each test administration was recorded. A 1-parameter item response theory model was used to examine the psychometric properties of the instruments, including precision and floor/ceiling effects.

Results: One hundred fifty-three orthopaedic trauma patients participated in the study. Mean test administration time for PROMIS PF CAT was 44 seconds versus 599 seconds for sMFA (P < 0.05). Both instruments showed extremely high item reliability (Cronbach alpha = 0.98). In terms of instrument coverage, neither instrument showed any floor effect; however, the sMFA revealed 14.4% ceiling effect, whereas the PROMIS PF CAT had no appreciable ceiling effect.

Conclusions: Administered by electronic means, the PROMIS PF CAT required less than one-tenth the amount of time for patients to complete than the sMFA while achieving equally high reliability and less ceiling effects. The PROMIS PF CAT is a very attractive and innovative method for assessing patient-reported outcomes with minimal burden to patients.

PubMed Disclaimer

Comment in

  • Invited Commentary.
    Horwitz DS, Suk M. Horwitz DS, et al. J Orthop Trauma. 2014 Aug;28(8):443. doi: 10.1097/01.bot.0000452501.26264.5b. J Orthop Trauma. 2014. PMID: 26057883 No abstract available.
  • In response.
    Hung M, Stuart AR, Higgins TF, Saltzman CL, Kubiak EN. Hung M, et al. J Orthop Trauma. 2014 Aug;28(8):444. doi: 10.1097/01.bot.0000452502.03394.c8. J Orthop Trauma. 2014. PMID: 26057884 No abstract available.

Publication types