Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2014 Jan;15(1):15-20.
doi: 10.1097/PCC.0b013e3182976251.

Impact of positive end-expiratory pressure on cardiac index measured by ultrasound cardiac output monitor*

Affiliations

Impact of positive end-expiratory pressure on cardiac index measured by ultrasound cardiac output monitor*

Oscar A Ingaramo et al. Pediatr Crit Care Med. 2014 Jan.

Abstract

Objectives: To evaluate the impact of different levels of positive end-expiratory pressure on cardiac index in children receiving mechanical ventilation. To explore the effect of lung recruitment on the relationship between positive end-expiratory pressure and cardiac output.

Design: Prospective, single center, and interventional.

Setting: PICU in a tertiary care children's hospital.

Patients: Fifty mechanically ventilated, hemodynamically stable children between 1 month and 20 years old.

Interventions: Positive end-expiratory pressure was altered to levels of 0, 4, 8, and 12 cm H2O in random order. Cardiac output was measured at different levels of positive end-expiratory pressure by continuous wave Doppler ultrasound (ultrasound cardiac output monitor). Baseline vital signs were recorded, as well as cardiac index and dynamic compliance of the respiratory system at each positive end-expiratory pressure level.

Measurements and main results: Median cardiac index decreased marginally as positive end-expiratory pressure increased, with a median change in cardiac index of 0.4 (< 10%) between positive end-expiratory pressure of 0 and 12 cm H2O (p < 0.001). There was no difference in heart rate or blood pressure as positive end-expiratory pressure increased (p > 0.5). For a subset of 29 patients (58%) in whom the highest dynamic compliance was at a positive end-expiratory pressure of 4 or 8 cm H2O, there was no difference in cardiac index between positive end-expiratory pressure 4 below versus positive end-expiratory pressure at highest dynamic compliance, or cardiac index between positive end-expiratory pressure 4 above versus positive end-expiratory pressure at highest dynamic compliance (p > 0.2). Regardless of optimal dynamic compliance, cardiac index decreased as positive end-expiratory pressure increased (p = 0.02).

Conclusions: In hemodynamically stable mechanically ventilated children, although there is a statistically significant decrease in cardiac output as positive end-expiratory pressure is increased between 0 and 12 cm H2O, the mean change is less than 10%, and this is likely not clinically significant. In the presence of lung disease, intensive care physicians should feel less reluctant in their use of positive end-expiratory pressure for hemodynamically stable patients.

PubMed Disclaimer

Comment in

Publication types

LinkOut - more resources