Combined computed tomography and fluorodeoxyglucose positron emission tomography in the diagnosis of prosthetic valve endocarditis: a case series
- PMID: 24418206
- PMCID: PMC3899623
- DOI: 10.1186/1756-0500-7-32
Combined computed tomography and fluorodeoxyglucose positron emission tomography in the diagnosis of prosthetic valve endocarditis: a case series
Abstract
Background: The diagnosis of prosthetic valve endocarditis is challenging. The gold standard for prosthetic valve endocarditis diagnosis is trans-esophageal echocardiography. However, trans-esophageal echocardiography may result in negative findings or yield images difficult to differentiate from thrombus in patients with prosthetic valve endocarditis. Combined computed tomography and fluorodeoxyglucose positron emission tomography is a potentially promising diagnostic tool for several infectious conditions and it has also been employed in patients with prosthetic valve endocarditis but data are still scant.
Case presentations: We reviewed the charts of 6 patients with prosthetic aortic valves evaluated for suspicion of prosthetic valve endocarditis, at two different hospital, over a 3-year period. We found 3 patients with early-onset PVE cases and blood cultures yielding Pseudomonas aeruginosa, Staphylococcus epidermidis and Staphylococcus lugdunensis, respectively; and 3 late-onset cases in the remaining 3 patients with isolation in the blood of Streptococcus bovis, Candida albicans and P. aeruginosa, respectively. Initial trans-esophageal echocardiography was negative in all the patients, while fluorodeoxyglucose positron emission tomography showed images suspicious for prosthetic valve endocarditis. In 4 out of 6 patients valve replacement was done with histology confirming the prosthetic valve endocarditis diagnosis. After an adequate course of antibiotic therapy fluorodeoxyglucose positron emission tomography showed resolution of prosthetic valve endocarditis in all the patients.
Conclusion: Our experience confirms the potential role of fluoroseoxyglucose positron emission tomography in the diagnosis and follow-up of prosthetic valve endocarditis.
Figures
Similar articles
-
Improving the Diagnostic Performance of 18F-Fluorodeoxyglucose Positron-Emission Tomography/Computed Tomography in Prosthetic Heart Valve Endocarditis.Circulation. 2018 Oct 2;138(14):1412-1427. doi: 10.1161/CIRCULATIONAHA.118.035032. Circulation. 2018. PMID: 30018167
-
Prosthetic valve endocarditis: positron emission tomography/computed tomography as a new golden grail.Acta Cardiol. 2018 Apr;73(2):109-114. doi: 10.1080/00015385.2017.1351255. Epub 2017 Aug 22. Acta Cardiol. 2018. PMID: 28826332 Review.
-
Diagnostic value of 18F-FDG PET/cardiac CT in late prosthetic aortic endocarditis with periprosthetic abscess.Rev Esp Med Nucl Imagen Mol. 2017 Jan-Feb;36(1):59-60. doi: 10.1016/j.remn.2016.06.007. Epub 2016 Aug 1. Rev Esp Med Nucl Imagen Mol. 2017. PMID: 27492856 English, Spanish. No abstract available.
-
18-Fluoro-2-deoxyglucose positron emission tomography-computed tomography: an additional tool in the diagnosis of prosthetic valve endocarditis.Int J Infect Dis. 2014 Nov;28:219-24. doi: 10.1016/j.ijid.2014.04.028. Epub 2014 Aug 2. Int J Infect Dis. 2014. PMID: 25093540
-
Does positron emission tomography/computed tomography aid the diagnosis of prosthetic valve infective endocarditis?Interact Cardiovasc Thorac Surg. 2016 Oct;23(4):648-52. doi: 10.1093/icvts/ivw177. Epub 2016 May 31. Interact Cardiovasc Thorac Surg. 2016. PMID: 27252241 Review.
Cited by
-
Nuclear medicine in diagnosis of prosthetic valve endocarditis: an update.Biomed Res Int. 2015;2015:127325. doi: 10.1155/2015/127325. Epub 2015 Jan 28. Biomed Res Int. 2015. PMID: 25695043 Free PMC article. Review.
-
Pseudomonas aeruginosa Infective Endocarditis Following Aortic Valve Implantation: A Note of Caution.Open Cardiovasc Med J. 2016 Feb 19;10:28-34. doi: 10.2174/1874192401610010028. eCollection 2016. Open Cardiovasc Med J. 2016. PMID: 27014375 Free PMC article.
-
Infective Endocarditis After Melody Valve Implantation in the Pulmonary Position: A Systematic Review.J Am Heart Assoc. 2018 Jun 22;7(13):e008163. doi: 10.1161/JAHA.117.008163. J Am Heart Assoc. 2018. PMID: 29934419 Free PMC article.
-
Contemporary Role of Positron Emission Tomography (PET) in Endocarditis: A Narrative Review.J Clin Med. 2024 Jul 15;13(14):4124. doi: 10.3390/jcm13144124. J Clin Med. 2024. PMID: 39064164 Free PMC article. Review.
-
Standardized uptake values in FDG PET/CT for prosthetic heart valve endocarditis: a call for standardization.J Nucl Cardiol. 2018 Dec;25(6):2084-2091. doi: 10.1007/s12350-017-0932-x. Epub 2017 Jun 5. J Nucl Cardiol. 2018. PMID: 28585026 Free PMC article.
References
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical