Tight computerized versus conventional glucose control in the ICU: a randomized controlled trial
- PMID: 24420499
- DOI: 10.1007/s00134-013-3189-0
Tight computerized versus conventional glucose control in the ICU: a randomized controlled trial
Abstract
Purpose: The blood glucose target range and optimal method to reach this range remain a matter of debate in the intensive care unit (ICU). A computer decision support system (CDSS) might improve the outcome of ICU patients through facilitation of a tighter blood glucose control.
Methods: We conducted a multi-center randomized trial in 34 French ICU. Adult patients expected to require treatment in the ICU for at least 3 days were randomly assigned without blinding to undergo tight computerized glucose control with the CDSS (TGC) or conventional glucose control (CGC), with blood glucose targets of 4.4-6.1 and <10.0 mmol/L, respectively. The primary outcome was all-cause death within 90 days after ICU admission.
Results: Of the 2,684 patients who underwent randomization to the TGC and CGC treatment groups, primary outcome was available for 1,335 and 1,311 patients, respectively. The baseline characteristics of these treatment groups were similar in terms of age (61 ± 16 years), SAPS II (51 ± 19), percentage of surgical admissions (40.0%) and proportion of diabetic patients (20.3%). A total of 431 (32.3%) patients in the TGC group and 447 (34.1%) in the CGC group had died by day 90 (odds ratio for death in the TGC 0.92; 95% confidence interval 0.78-1.78; p = 0.32). Severe hypoglycemia (<2.2 mmol/L) occurred in 174 of 1,317 patients (13.2%) in the TGC group and 79 of 1,284 patients (6.2%) in the CGC group (p < 0.001).
Conclusions: Tight computerized glucose control with the CDSS did not significantly change 90-day mortality and was associated with more frequent severe hypoglycemia episodes in comparison with conventional glucose control.
Trial registration: ClinicalTrials.gov NCT01002482.
Comment in
-
The responsibility of undertaking large randomized controlled trials.Intensive Care Med. 2014 Feb;40(2):266-268. doi: 10.1007/s00134-013-3180-9. Epub 2014 Jan 14. Intensive Care Med. 2014. PMID: 24420498 No abstract available.
-
Comment on Kalfon et al.: Tight computerized versus conventional glucose control in the ICU: a randomized controlled trial.Intensive Care Med. 2014 Jun;40(6):922. doi: 10.1007/s00134-014-3302-z. Epub 2014 May 7. Intensive Care Med. 2014. PMID: 24802665 No abstract available.
References
Publication types
MeSH terms
Substances
Associated data
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical