Application of the N-point moving average method for brachial pressure waveform-derived estimation of central aortic systolic pressure
- PMID: 24420554
- DOI: 10.1161/HYPERTENSIONAHA.113.02229
Application of the N-point moving average method for brachial pressure waveform-derived estimation of central aortic systolic pressure
Abstract
The N-point moving average (NPMA) is a mathematical low-pass filter that can smooth peaked noninvasively acquired radial pressure waveforms to estimate central aortic systolic pressure using a common denominator of N/4 (where N=the acquisition sampling frequency). The present study investigated whether the NPMA method can be applied to brachial pressure waveforms. In the derivation group, simultaneously recorded invasive high-fidelity brachial and central aortic pressure waveforms from 40 subjects were analyzed to identify the best common denominator. In the validation group, the NPMA method with the obtained common denominator was applied on noninvasive brachial pressure waveforms of 100 subjects. Validity was tested by comparing the noninvasive with the simultaneously recorded invasive central aortic systolic pressure. Noninvasive brachial pressure waveforms were calibrated to the cuff systolic and diastolic blood pressures. In the derivation study, an optimal denominator of N/6 was identified for NPMA to derive central aortic systolic pressure. The mean difference between the invasively/noninvasively estimated (N/6) and invasively measured central aortic systolic pressure was 0.1±3.5 and -0.6±7.6 mm Hg in the derivation and validation study, respectively. It satisfied the Association for the Advancement of Medical Instrumentation standard of 5±8 mm Hg. In conclusion, this method for estimating central aortic systolic pressure using either invasive or noninvasive brachial pressure waves requires a common denominator of N/6. By integrating the NPMA method into the ordinary oscillometric blood pressure determining process, convenient noninvasive central aortic systolic pressure values could be obtained with acceptable accuracy.
Keywords: arterial pressure; blood pressure monitoring; mathematical computing.
Comment in
-
Moving on--on average in the right direction?: noninvasive methods to estimate central blood pressure.Hypertension. 2014 Apr;63(4):665-7. doi: 10.1161/HYPERTENSIONAHA.113.02885. Epub 2014 Jan 13. Hypertension. 2014. PMID: 24420555 No abstract available.
Similar articles
-
Central blood pressure estimation by using N-point moving average method in the brachial pulse wave.Hypertens Res. 2015 May;38(5):336-41. doi: 10.1038/hr.2015.5. Epub 2015 Feb 19. Hypertens Res. 2015. PMID: 25693855
-
Development and validation of a novel method to derive central aortic systolic pressure from the radial pressure waveform using an n-point moving average method.J Am Coll Cardiol. 2011 Feb 22;57(8):951-61. doi: 10.1016/j.jacc.2010.09.054. J Am Coll Cardiol. 2011. PMID: 21329842
-
Measurement of central aortic pulse pressure: noninvasive brachial cuff-based estimation by a transfer function vs. a novel pulse wave analysis method.Am J Hypertens. 2012 Nov;25(11):1162-9. doi: 10.1038/ajh.2012.116. Epub 2012 Aug 9. Am J Hypertens. 2012. PMID: 22874891
-
Arterial pressure waveforms in hypertension.Minerva Med. 2003 Aug;94(4):229-50. Minerva Med. 2003. PMID: 14605588 Review.
-
Clinical measurement of arterial stiffness obtained from noninvasive pressure waveforms.Am J Hypertens. 2005 Jan;18(1 Pt 2):3S-10S. doi: 10.1016/j.amjhyper.2004.10.009. Am J Hypertens. 2005. PMID: 15683725 Review.
Cited by
-
Central blood pressure for the management of hypertension: Is it a practical clinical tool in current practice?J Clin Hypertens (Greenwich). 2020 Mar;22(3):391-406. doi: 10.1111/jch.13758. Epub 2019 Dec 16. J Clin Hypertens (Greenwich). 2020. PMID: 31841279 Free PMC article. Clinical Trial.
-
Aortic systolic and pulse pressure invasively and non-invasively obtained: Comparative analysis of recording techniques, arterial sites of measurement, waveform analysis algorithms and calibration methods.Front Physiol. 2023 Jan 16;14:1113972. doi: 10.3389/fphys.2023.1113972. eCollection 2023. Front Physiol. 2023. PMID: 36726850 Free PMC article.
-
Central blood pressure estimation by using N-point moving average method in the brachial pulse wave.Hypertens Res. 2015 May;38(5):336-41. doi: 10.1038/hr.2015.5. Epub 2015 Feb 19. Hypertens Res. 2015. PMID: 25693855
-
2019 Consensus of the Taiwan Hypertension Society and Taiwan Society of Cardiology on the Clinical Application of Central Blood Pressure in the Management of Hypertension.Acta Cardiol Sin. 2019 May;35(3):234-243. doi: 10.6515/ACS.201905_35(3).20190415B. Acta Cardiol Sin. 2019. PMID: 31249456 Free PMC article. Review.
-
[Research progress in central aortic pressure estimation algorithms].Sheng Wu Yi Xue Gong Cheng Xue Za Zhi. 2025 Jun 25;42(3):643-650. doi: 10.7507/1001-5515.202407014. Sheng Wu Yi Xue Gong Cheng Xue Za Zhi. 2025. PMID: 40566789 Free PMC article. Review. Chinese.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources