Positioning in breast MR imaging to optimize image quality
- PMID: 24428300
- DOI: 10.1148/rg.341125193
Positioning in breast MR imaging to optimize image quality
Abstract
Improper positioning of the breasts in a dedicated breast coil causes inhomogeneous fat saturation as well as other artifacts that decrease the sensitivity of breast magnetic resonance imaging. Improper positioning can create artifacts that can obscure a malignancy or cause it to be missed. Goals of proper positioning include imaging the maximum area of breast tissue, minimizing skin folds, and achieving homogeneous fat suppression and nondeformed breast parenchyma. Review of prior images gives the technologist an impression of what the positioning and imaging challenges may be in each patient before the patient enters the imaging unit. Checking the triplane localizer images and repositioning as necessary before any diagnostic or interventional imaging is key. Using a fat saturation pad, changing the arm position, or "rolling" the patient may be considered in difficult cases. Padding to support the patient in an oblique position, using angled sponges to increase breast compression thickness, and raising the grid to access posterior lesions may be helpful in targeting difficult-to-access lesions for biopsy. Using the presented positioning techniques and suggestions, in addition to strict attention to detail before imaging, will improve image quality, decrease imaging time and suboptimal images, and limit the need for repeat imaging studies.
© RSNA, 2014.
Similar articles
-
Supine breast MRI and assessment of future clinical applications.Eur J Radiol. 2012 Sep;81 Suppl 1:S153-5. doi: 10.1016/S0720-048X(12)70064-5. Eur J Radiol. 2012. PMID: 23083571 No abstract available.
-
A simple method to visualize image quality degradation for off-center regions in open-configuration MR systems.J Am Coll Radiol. 2014 Jul;11(7):742-4. doi: 10.1016/j.jacr.2014.04.002. Epub 2014 Jun 2. J Am Coll Radiol. 2014. PMID: 24889473 No abstract available.
-
How to optimize clinical breast MR imaging practices and techniques on Your 1.5-T system.Radiographics. 2006 Sep-Oct;26(5):1469-84. doi: 10.1148/rg.265055176. Radiographics. 2006. PMID: 16973776 Review.
-
Fat-suppressed MR images of both hands obtained using CHESS can be improved by rice pads.Eur J Radiol. 2012 Sep;81(9):2318-22. doi: 10.1016/j.ejrad.2011.06.021. Epub 2011 Jun 25. Eur J Radiol. 2012. PMID: 21708440
-
Imaging techniques for breast MR imaging.Magn Reson Imaging Clin N Am. 1994 Nov;2(4):511-25. Magn Reson Imaging Clin N Am. 1994. PMID: 7489305 Review.
Cited by
-
Advanced Diffusion-Weighted Imaging Sequences for Breast MRI: Comprehensive Comparison of Improved Sequences and Ultra-High B-Values to Identify the Optimal Combination.Diagnostics (Basel). 2023 Feb 7;13(4):607. doi: 10.3390/diagnostics13040607. Diagnostics (Basel). 2023. PMID: 36832095 Free PMC article.
-
Magnetic resonance imaging in the evaluation of pathologic nipple discharge: indications and imaging findings.Br J Radiol. 2021 Apr 1;94(1120):20201013. doi: 10.1259/bjr.20201013. Epub 2021 Feb 5. Br J Radiol. 2021. PMID: 33544650 Free PMC article. Review.
-
MRI-guided breast biopsy based on diffusion-weighted imaging: a feasibility study.Eur Radiol. 2021 May;31(5):2645-2656. doi: 10.1007/s00330-020-07396-2. Epub 2020 Oct 30. Eur Radiol. 2021. PMID: 33128183 Free PMC article.
-
Quantification of breast stiffness using MR elastography at 3 Tesla with a soft sternal driver: A reproducibility study.J Magn Reson Imaging. 2017 May;45(5):1379-1384. doi: 10.1002/jmri.25511. Epub 2016 Oct 25. J Magn Reson Imaging. 2017. PMID: 27779802 Free PMC article.
-
Magnetic Resonance Imaging-Guided Breast Interventions: Role in Biopsy Targeting and Lumpectomies.Magn Reson Imaging Clin N Am. 2015 Nov;23(4):547-61. doi: 10.1016/j.mric.2015.05.004. Epub 2015 Jul 8. Magn Reson Imaging Clin N Am. 2015. PMID: 26499274 Free PMC article. Review.