Procedural guidance using advance imaging techniques for percutaneous edge-to-edge mitral valve repair
- PMID: 24430014
- DOI: 10.1007/s11886-013-0452-5
Procedural guidance using advance imaging techniques for percutaneous edge-to-edge mitral valve repair
Abstract
The complexity of structural heart disease interventions such as edge-to edge mitral valve repair requires integration of multiple highly technical imaging modalities. Real time imaging with 3-dimensional (3D) echocardiography is a relatively new technique that first, allows clear volumetric imaging of target structures such as the mitral valve for both pre-procedural diagnosis and planning in patients with degenerative or functional mitral valve regurgitation. Secondly it provides intra-procedural, real-time panoramic volumetric 3D view of structural heart disease targets that facilitates eye-hand coordination while manipulating devices within the heart. X-ray fluoroscopy and RT 3D TEE images are used in combination to display specific targets and movement of catheter based technologies in 3D space. This integration requires at least two different image display monitors and mentally fusing the individual datasets by the operator. Combined display technology such as this, allow rotation and orientation of both dataset perspectives necessary to define targets and guidance of structural disease device procedures. The inherently easy concept of direct visual feedback and eye-hand coordination allows safe and efficient completion of MitraClip procedures. This technology is now merged into a single structural heart disease guidance mode called EchoNavigator(TM) (Philips Medical Imaging Andover, MA). These advanced imaging techniques have revolutionized the field of structural heart disease interventions and this experience is exemplified by a cooperative imaging approach used for guidance of edge-to-edge mitral valve repair procedures.
Similar articles
-
3D transesophageal echocardiography: A new imaging tool for assessment of mitral regurgitation and for guiding percutaneous edge-to-edge mitral valve repair.Prog Cardiovasc Dis. 2017 Nov-Dec;60(3):305-321. doi: 10.1016/j.pcad.2017.10.001. Epub 2017 Oct 19. Prog Cardiovasc Dis. 2017. PMID: 29056395 Review.
-
Transcatheter Mitral Valve Repair Using the Edge-to-Edge Clip.J Am Soc Echocardiogr. 2018 Apr;31(4):434-453. doi: 10.1016/j.echo.2018.01.012. Epub 2018 Mar 1. J Am Soc Echocardiogr. 2018. PMID: 29482977 Review.
-
Percutaneous Transcatheter Edge-to-Edge MitraClip Technique: A Practical "Step-by-Step" 3-Dimensional Transesophageal Echocardiography Guide.Mayo Clin Proc. 2019 Jan;94(1):89-102. doi: 10.1016/j.mayocp.2018.10.007. Mayo Clin Proc. 2019. PMID: 30611459 Review.
-
Optimized guidance of percutaneous edge-to edge repair of the mitral valve using real-time 3-D transesophageal echocardiography.Clin Res Cardiol. 2011 Aug;100(8):675-81. doi: 10.1007/s00392-011-0296-1. Epub 2011 Mar 3. Clin Res Cardiol. 2011. PMID: 21369924
-
Incremental value of 3-D transesophageal echocardiographic imaging of the mitral valve.Curr Cardiol Rep. 2014 Jan;16(1):439. doi: 10.1007/s11886-013-0439-2. Curr Cardiol Rep. 2014. PMID: 24292888 Review.
Cited by
-
Real-Time Monitoring and Step-by-Step Guidance for Transapical Mitral Valve Edge-to-Edge Repair Using Transesophageal Echocardiography.J Interv Cardiol. 2021 Apr 21;2021:6659261. doi: 10.1155/2021/6659261. eCollection 2021. J Interv Cardiol. 2021. PMID: 33976590 Free PMC article. Review.
-
Safety and efficacy of transseptal puncture guided by real-time fusion of echocardiography and fluoroscopy.Neth Heart J. 2017 Feb;25(2):131-136. doi: 10.1007/s12471-016-0937-0. Neth Heart J. 2017. PMID: 27966185 Free PMC article.
-
MitraClip step by step; how to simplify the procedure.Neth Heart J. 2017 Feb;25(2):125-130. doi: 10.1007/s12471-016-0930-7. Neth Heart J. 2017. PMID: 27933588 Free PMC article. Review.
-
Role of 3D Echocardiography in Cardiac Surgery: Strengths and Limitations.Curr Anesthesiol Rep. 2017;7(3):291-298. doi: 10.1007/s40140-017-0226-5. Epub 2017 Jul 21. Curr Anesthesiol Rep. 2017. PMID: 28890667 Free PMC article. Review.
-
Demonstration of Use of a Novel 3D Printed Simulator for Mitral Valve Transcatheter Edge-to-Edge Repair (TEER).Materials (Basel). 2022 Jun 17;15(12):4284. doi: 10.3390/ma15124284. Materials (Basel). 2022. PMID: 35744343 Free PMC article.
References
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources