Systematic review of uncalibrated arterial pressure waveform analysis to determine cardiac output and stroke volume variation
- PMID: 24431387
- DOI: 10.1093/bja/aet429
Systematic review of uncalibrated arterial pressure waveform analysis to determine cardiac output and stroke volume variation
Abstract
The FloTrac/Vigileo™, introduced in 2005, uses arterial pressure waveform analysis to calculate cardiac output (CO) and stroke volume variation (SVV) without external calibration. The aim of this systematic review is to evaluate the performance of the system. Sixty-five full manuscripts on validation of CO measurements in humans, published in English, were retrieved; these included 2234 patients and 44,592 observations.
Results: have been analysed according to underlying patient conditions, that is, general critical illness and surgery as normodynamic conditions, cardiac and (post)cardiac surgery as hypodynamic conditions, and liver surgery and sepsis as hyperdynamic conditions, and subsequently released software versions. Eight studies compared SVV with other dynamic indices. CO, bias, precision, %error, correlation, and concordance differed among underlying conditions, subsequent software versions, and their interactions, suggesting increasing accuracy and precision, particularly in hypo- and normodynamic conditions. The bias and the trending capacity remain dependent on (changes in) vascular tone with most recent software. The SVV only moderately agreed with other dynamic indices, although it was helpful in predicting fluid responsiveness in 85% of studies addressing this. Since its introduction, the performance of uncalibrated FloTrac/Vigileo™ has improved particularly in hypo- and normodynamic conditions. A %error at or below 30% with most recent software allows sufficiently accurate and precise CO measurements and trending for routine clinical use in normo- and hypodynamic conditions, in the absence of large changes in vascular tone. The SVV may usefully supplement these measurements.
Keywords: comparing cardiac output; haemodynamic optimization; stroke volume variations; uncalibrated arterial pressure waveform analysis.
Similar articles
-
Fourth Generation FloTrac Software Pulse Contour Analysis for Measuring and Trending Cardiac Output: A Method Comparison Study.Acta Anaesthesiol Scand. 2025 Jul;69(6):e70077. doi: 10.1111/aas.70077. Acta Anaesthesiol Scand. 2025. PMID: 40561193 Free PMC article.
-
[Volume and health outcomes: evidence from systematic reviews and from evaluation of Italian hospital data].Epidemiol Prev. 2013 Mar-Jun;37(2-3 Suppl 2):1-100. Epidemiol Prev. 2013. PMID: 23851286 Italian.
-
Evaluation of the Fourth-Generation FloTrac/Vigileo System in Comparison With the Intermittent Bolus Thermodilution Method in Patients Undergoing Cardiac Surgery.J Cardiothorac Vasc Anesth. 2019 Apr;33(4):953-960. doi: 10.1053/j.jvca.2018.06.017. Epub 2018 Jun 28. J Cardiothorac Vasc Anesth. 2019. PMID: 30077561
-
The Black Book of Psychotropic Dosing and Monitoring.Psychopharmacol Bull. 2024 Jul 8;54(3):8-59. Psychopharmacol Bull. 2024. PMID: 38993656 Free PMC article. Review.
-
Ventilator Management(Archived).2023 Mar 27. In: StatPearls [Internet]. Treasure Island (FL): StatPearls Publishing; 2025 Jan–. 2023 Mar 27. In: StatPearls [Internet]. Treasure Island (FL): StatPearls Publishing; 2025 Jan–. PMID: 28846232 Free Books & Documents.
Cited by
-
Prediction of postoperative complications after hepatectomy with dynamic monitoring of central venous oxygen saturation.BMC Surg. 2023 Nov 14;23(1):343. doi: 10.1186/s12893-023-02238-6. BMC Surg. 2023. PMID: 37957615 Free PMC article.
-
Intra-arterial blood pressure measurement: sources of error and solutions.Med Biol Eng Comput. 2022 Apr;60(4):1123-1138. doi: 10.1007/s11517-022-02509-z. Epub 2022 Mar 2. Med Biol Eng Comput. 2022. PMID: 35235133
-
Internal jugular vein collapsibility does not predict fluid responsiveness in spontaneously breathing patients after cardiac surgery.J Clin Monit Comput. 2023 Dec;37(6):1563-1571. doi: 10.1007/s10877-023-01066-6. Epub 2023 Aug 12. J Clin Monit Comput. 2023. PMID: 37572237
-
The Effect of Goal-directed Fluid Management based on Stroke Volume Variation on ICU Length of Stay in Elderly Patients Undergoing Elective Craniotomy: A Randomized Controlled Trial.Indian J Crit Care Med. 2023 Oct;27(10):709-716. doi: 10.5005/jp-journals-10071-24551. Indian J Crit Care Med. 2023. PMID: 37908429 Free PMC article.
-
A multimodal stacked ensemble model for cardiac output prediction utilizing cardiorespiratory interactions during general anesthesia.Sci Rep. 2024 Mar 29;14(1):7478. doi: 10.1038/s41598-024-57971-6. Sci Rep. 2024. PMID: 38553509 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical