Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2013 Oct;7(4):285-8.
doi: 10.1007/s11832-013-0506-7. Epub 2013 Jul 3.

Eight plate should not be used for treating leg length discrepancy

Affiliations

Eight plate should not be used for treating leg length discrepancy

Henrik Lauge-Pedersen et al. J Child Orthop. 2013 Oct.

Abstract

Purpose: The Blount staple has been widely used for treating angular deformities and leg length discrepancy (LLD) of the lower limbs. In recent years, the Eight plate has replaced the Blount staple for treating angular deformities in many centres. Although not described in the literature, it has been proposed that the Eight plate could also be used for treating LLD. We studied the effectiveness of the device for this indication.

Methods: Ten patients with LLD were included prospectively. Medial and lateral plates were inserted for symmetrical growth reduction and the patients were followed by radiostereometric analysis (RSA) 0, 3, 6, 9, 12, 24, 52 and 80 weeks postoperatively. The error of measurement with this technique is less than 0.05 mm.

Results: Case 1 continued to grow an average of 0.08 mm per week (6.7 mm longitudinal growth in 1.5 years) postoperatively, while Case 2 showed 0.07 mm longitudinal growth per week (5.6 mm longitudinal growth in 1.5 years). The longitudinal growth, in both children, showed only slight growth retardation throughout the follow-up period. The study was interrupted and no further subjects were included after the results indicated that only minor growth reduction had occurred in both patients.

Conclusion: The Eight plate does not significantly reduce growth when applied both medially and laterally in a symmetrical way at the proximal tibial physis.

Keywords: Eight plate; Leg length discrepancy; Physiodesis; Radiostereometric analysis.

PubMed Disclaimer

Figures

Fig. 1
Fig. 1
Longitudinal growth of the proximal tibia, measured using radiostereometric analysis (RSA). a Typical growth retardation of the proximal tibia after percutaneous physiodesis, b Case 1 and c Case 2
Fig. 2
Fig. 2
a Case 1: an 11-year-old boy treated with a medial and lateral Eight plate and tantalum markers for radiostereometric analysis (RSA); left postoperatively, right at 1-year follow-up, showing widening of the screws. b Case 2: an 11-year-old girl treated with a medial and lateral Eight plate and tantalum markers for RSA; left postoperatively, right at 1-year follow-up, showing widening of the screws

References

    1. Phemister DB. Operative arrestment of longitudinal growth of bones in the treatment of deformities. J Bone Joint Surg. 1993;15:1–15.
    1. Blount WP, Clarke GR. Control of bone growth by epiphyseal stapling; a preliminary report. J Bone Joint Surg Am. 1949;31A:464–478. - PubMed
    1. Canale ST, Christian CA. Techniques for epiphysiodesis about the knee. Clin Orthop Relat Res. 1990;255:81–85. - PubMed
    1. Atar D, Lehman WB, Grant AD, Strongwater A. Pediatric update #12. A simplified method for percutaneous epiphysiodesis. Orthop Rev. 1990;19:358–359. - PubMed
    1. Canale ST, Russell TA, Holcomb RL. Percutaneous epiphysiodesis: experimental study and preliminary clinical results. J Pediatr Orthop. 1986;6:150–156. doi: 10.1097/01241398-198603000-00006. - DOI - PubMed

LinkOut - more resources