Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Observational Study
. 2014 Apr;164(4):730-736.e1.
doi: 10.1016/j.jpeds.2013.11.072. Epub 2014 Jan 14.

Oxygen saturation targeting in preterm infants receiving continuous positive airway pressure

Affiliations
Observational Study

Oxygen saturation targeting in preterm infants receiving continuous positive airway pressure

Kathleen Lim et al. J Pediatr. 2014 Apr.

Abstract

Objective: The precision of oxygen saturation (SpO2) targeting in preterm infants on continuous positive airway pressure (CPAP) is incompletely characterized. We therefore evaluated SpO2 targeting in infants solely receiving CPAP, aiming to describe their SpO2 profile, to document the frequency of prolonged hyperoxia and hypoxia episodes and of fraction of inspired oxygen (FiO2) adjustments, and to explore the relationships with neonatal intensive care unit operational factors.

Study design: Preterm infants <37 weeks' gestation in 2 neonatal intensive care units were studied if they were receiving CPAP and in supplemental oxygen at the beginning of each 24-hour recording. SpO2, heart rate, and FiO2 were recorded (sampling interval 1-2 seconds). We measured the proportion of time spent in predefined SpO2 ranges, the frequency of prolonged episodes (≥30 seconds) of SpO2 deviation, and the effect of operational factors including nurse-patient ratio.

Results: A total of 4034 usable hours of data were recorded from 45 infants of gestation 30 (27-32) weeks (median [IQR]). When requiring supplemental oxygen, infants were in the target SpO2 range (88%-92%) for only 31% (19%-39%) of total recording time, with 48 (6.9-90) episodes per 24 hours of severe hyperoxia (SpO2 ≥98%), and 9.0 (1.6-21) episodes per 24 hours of hypoxia (SpO2 <80%). An increased frequency of prolonged hyperoxia in supplemental oxygen was noted when nurses were each caring for more patients. Adjustments to FiO2 were made 25 (16-41) times per day.

Conclusion: SpO2 targeting is challenging in preterm infants receiving CPAP support, with a high proportion of time spent outside the target range and frequent prolonged hypoxic and hyperoxic episodes.

PubMed Disclaimer

Publication types