Resolution of G gamma and A gamma foetal haemoglobin tetramers in immobilized pH gradients
- PMID: 2443526
- DOI: 10.1016/s0021-9673(01)96506-9
Resolution of G gamma and A gamma foetal haemoglobin tetramers in immobilized pH gradients
Abstract
Intact tetramers of foetal haemoglobin (G gamma, A gamma and the mutant A gamma T) can be separated by isoelectric focusing in immobilized pH gradients over a very shallow pH interval (pH 7.35-7.55). The G gamma tetramer exhibits a lower pI (7.450) than the A gamma tetramer (pI 7.453); the delta pI between the two species is barely 0.003 of a pH unit, close to the theoretical resolution limit of the technique, delta pI = 0.001. Haem-free, denatured gamma chains exhibit a reversal in pI order, the A gamma chain being more acidic than the G gamma chains: this is attributed to preferential binding of detergent micelles to the more hydrophobic A gamma polypeptide. The advantage of the present technique is the simultaneous analysis of several samples (30-40 per gel slab) and the recovery of intact, haemoglobin tetramers for subsequent studies.
Similar articles
-
Isoelectric focusing in immobilized pH gradients: recent analytical and preparative developments.Anal Biochem. 1997 Apr 5;247(1):1-10. doi: 10.1006/abio.1997.2000. Anal Biochem. 1997. PMID: 9126363 Review.
-
Separation and characterization of a foetal haemoglobin variant by means of isoelectric focussing.Life Sci II. 1971 Feb 22;10(4):191-4. doi: 10.1016/0024-3205(71)90017-8. Life Sci II. 1971. PMID: 5575791 No abstract available.
-
N-terminal contributions of the gamma-subunit of fetal hemoglobin to its tetramer strength: remote effects at subunit contacts.Protein Sci. 2002 Jan;11(1):27-35. doi: 10.1110/ps.30602. Protein Sci. 2002. PMID: 11742119 Free PMC article.
-
Fractionation of carrier ampholytes in multicompartment electrolyzers with isoelectric membranes.Electrophoresis. 1995 Oct;16(10):1930-4. doi: 10.1002/elps.11501601319. Electrophoresis. 1995. PMID: 8586068
-
Analysis of haemoglobin variants using immobilized pH gradients.Eur J Clin Chem Clin Biochem. 1993 Feb;31(2):91-6. doi: 10.1515/cclm.1993.31.2.91. Eur J Clin Chem Clin Biochem. 1993. PMID: 8467014
Cited by
-
Bistable isoelectric point photoswitching in green fluorescent proteins observed by dynamic immunoprobed isoelectric focusing.J Am Chem Soc. 2012 Oct 24;134(42):17582-91. doi: 10.1021/ja3064292. Epub 2012 Oct 10. J Am Chem Soc. 2012. PMID: 23017083 Free PMC article.
-
Capillary array isoelectric focusing with laser-induced fluorescence detection: milli-pH unit resolution and yoctomole mass detection limits in a 32-channel system.Anal Bioanal Chem. 2010 Aug;397(8):3305-10. doi: 10.1007/s00216-010-3595-x. Epub 2010 Mar 25. Anal Bioanal Chem. 2010. PMID: 20336452 Free PMC article.
-
Combining high-throughput MALDI-TOF mass spectrometry and isoelectric focusing gel electrophoresis for virtual 2D gel-based proteomics.Methods. 2016 Jul 15;104:163-9. doi: 10.1016/j.ymeth.2016.01.013. Epub 2016 Jan 28. Methods. 2016. PMID: 26826592 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Research Materials
Miscellaneous