Abstract
Purpose: The airway scope (AWS) improves views of the larynx during orotracheal intubation. However, the role of the AWS in routine nasotracheal intubation has not been studied adequately.
Methods: One hundred and three patients undergoing dental and maxillofacial surgery that required general anesthesia and nasotracheal intubation were enrolled. The study was approved by our Institution Review Board, and written informed consent was obtained from all patients. We evaluated the success rate of AWS intubation and the incidence of difficult nasotracheal intubation using a modified intubation difficulty scale (IDS) to examine preoperative characteristics and intubation profiles. Categories were difficult intubation (IDS ≥5), mildly difficult (IDS = 1-4), and intubation without difficulty (IDS = 0). We also assessed the incidence of the use of Magill forceps or cuff inflation (the cuff of endotracheal tube is inflated with 10-15 ml air) to guide the endotracheal tube into the glottis.
Results: AWS nasotracheal intubation was 100% successful. The cuff inflation technique was used in 37 patients. Neither Magill forceps nor other devices were needed for any patient during AWS use. The incidence of difficult nasotracheal intubation was 10% (n = 10). Of the patients, 61% (n = 63) had mildly difficult intubation and 29% (n = 30) had no difficulty. Patients with difficult intubation were more likely to be male and to have a larger tongue and a higher Cormack grade than in the other two groups. Complications, involving minor soft tissue injury, were observed in only 1 patient (1%).
Conclusion: The AWS achieves a high success rate for nasotracheal intubation with cuff inflation in patients undergoing dental and maxillofacial surgery.
Comment in
-
Are videolaryngoscopes useful for nasotracheal intubation?J Anesth. 2014 Oct;28(5):647-9. doi: 10.1007/s00540-014-1808-8. Epub 2014 Mar 22. J Anesth. 2014. PMID: 24659307 No abstract available.
-
Nasotracheal intubation with airway scope.J Anesth. 2016 Apr;30(2):360. doi: 10.1007/s00540-014-1897-4. Epub 2014 Aug 12. J Anesth. 2016. PMID: 25112813 No abstract available.
-
In reply: Nasotracheal intubation with airway scope.J Anesth. 2016 Apr;30(2):361. doi: 10.1007/s00540-015-2104-y. Epub 2016 Feb 2. J Anesth. 2016. PMID: 26838138 No abstract available.
References
-
- Enomoto Y, Asai T, Arai T, Kamishima K, Okuda Y. Pentax-AWS, a new videolaryngoscope, is more effective than the Macintosh laryngoscope for tracheal intubation in patients with restricted neck movements: a randomized comparative study. Br J Anaesth. 2008;100:544–548. doi: 10.1093/bja/aen002. - DOI - PubMed