Whole-body simultaneous positron emission tomography (PET)-MR: optimization and adaptation of MRI sequences
- PMID: 24436150
- DOI: 10.1002/jmri.24308
Whole-body simultaneous positron emission tomography (PET)-MR: optimization and adaptation of MRI sequences
Abstract
The purpose of this article is to introduce the underlying challenges associated with the incorporation of magnetic resonance imaging (MRI) into the new hybrid imaging modality simultaneous positron emission tomography (PET)/MR and their impact on attenuation correction, sequence optimization, and protocol development. Many adjustments to MR sequences are necessary for optimal whole-body and fused image results.
Keywords: MRI; PET/MR; mMR; oncology; whole-body imaging.
Copyright © 2013 Wiley Periodicals, Inc.
Similar articles
-
Integrated whole-body PET/MR hybrid imaging: clinical experience.Invest Radiol. 2013 May;48(5):280-9. doi: 10.1097/RLI.0b013e3182845a08. Invest Radiol. 2013. PMID: 23442775
-
Simultaneous reconstruction of activity and attenuation for PET/MR.IEEE Trans Med Imaging. 2011 Mar;30(3):804-13. doi: 10.1109/TMI.2010.2095464. Epub 2010 Nov 29. IEEE Trans Med Imaging. 2011. PMID: 21118768
-
Segmentation-based attenuation correction in positron emission tomography/magnetic resonance: erroneous tissue identification and its impact on positron emission tomography interpretation.Invest Radiol. 2015 May;50(5):339-46. doi: 10.1097/RLI.0000000000000131. Invest Radiol. 2015. PMID: 25585210
-
Integrated PET/MR.J Magn Reson Imaging. 2014 Feb;39(2):243-58. doi: 10.1002/jmri.24523. Epub 2013 Dec 12. J Magn Reson Imaging. 2014. PMID: 24338921 Review.
-
Initial experience of MR/PET in a clinical cancer center.J Magn Reson Imaging. 2014 Apr;39(4):768-80. doi: 10.1002/jmri.24334. Epub 2013 Sep 4. J Magn Reson Imaging. 2014. PMID: 24006287 Review.
Cited by
-
MR-PET of the body: Early experience and insights.Eur J Radiol Open. 2014 Sep 16;1:28-39. doi: 10.1016/j.ejro.2014.09.001. eCollection 2014. Eur J Radiol Open. 2014. PMID: 26937425 Free PMC article. Review.
-
Indeterminate Findings on Oncologic PET/CT: What Difference Does PET/MRI Make?Nucl Med Mol Imaging. 2016 Dec;50(4):292-299. doi: 10.1007/s13139-016-0405-1. Epub 2016 Feb 22. Nucl Med Mol Imaging. 2016. PMID: 27994684 Free PMC article.
-
Diagnostic performance of PET/CT and PET/MR in the management of ovarian carcinoma-a literature review.Abdom Radiol (NY). 2021 Jun;46(6):2323-2349. doi: 10.1007/s00261-020-02847-2. Epub 2020 Nov 11. Abdom Radiol (NY). 2021. PMID: 33175199 Review.
-
Applications of PET-MRI in musculoskeletal disease.J Magn Reson Imaging. 2018 Jul;48(1):27-47. doi: 10.1002/jmri.26183. J Magn Reson Imaging. 2018. PMID: 29969193 Free PMC article. Review.
-
Optimized workflow and imaging protocols for whole-body oncologic PET/MRI.Jpn J Radiol. 2016 Nov;34(11):754-762. doi: 10.1007/s11604-016-0584-9. Epub 2016 Oct 6. Jpn J Radiol. 2016. PMID: 27714486
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical