Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Randomized Controlled Trial
. 2014;11(7):460-8.
doi: 10.1080/15459624.2013.875185.

Repetitive box lifting performance is impaired in a hot environment: implications for altered work-rest cycles

Affiliations
Randomized Controlled Trial

Repetitive box lifting performance is impaired in a hot environment: implications for altered work-rest cycles

Carl M Maresh et al. J Occup Environ Hyg. 2014.

Abstract

This study investigated the effects of environmental temperature on repetitive box lifting (RBL) performance, associated stress hormone and creatine kinase (CK) responses. Ten healthy males performed two experimental trials in a random crossover design. The trials consisted of three 40 min (10 min sitting, 20 min standing, and 10 min RBL) circuits performed in either 23 °C or 38 °C followed by a 180 min seated recovery period in 23 °C. RBL performance (i.e., number of boxes lifted) was reduced (p ≤ 0.05) in 38 °C compared to the 23 °C trial. Physiological Strain Index was significantly different between trials (38 °C: 8.5 ± 1.1 versus 23 °C: 7.2 ± 0.7; p ≤ 0.01). Plasma testosterone was elevated (p ≤ 0.05) across both trials and then decreased at 60 min recovery, compared to pre-exercise (PRE) measures, but was higher (p ≤ 0.05) during the 38 °C trial. Plasma cortisol increased (p ≤ 0.05) at 60 min during both trials and remained elevated until 120 min in 23 °C, and until 60 min recovery in 38 °C. Serum CK was greater through 48 hr post compared to PRE values in both trials. Thus, 10 min RBL performance was reduced in 38 °C despite the 30-min rest periods between RBL intervals. Plasma testosterone and cortisol were generally higher during the 38 °C trial, suggesting a greater stress response. Additional research is needed to determine optimal work:rest cycles for maximizing work performance in thermally oppressive environments.

Keywords: cortisol; creatine kinase; occupational performance; testosterone.

PubMed Disclaimer

Publication types

LinkOut - more resources