Pilot task-based assessment of noise levels among firefighters
- PMID: 24443622
- PMCID: PMC3891787
- DOI: 10.1016/j.ergon.2012.05.004
Pilot task-based assessment of noise levels among firefighters
Abstract
Purpose: Over one million American firefighters are routinely exposed to various occupational hazards agents. While efforts have been made to identify and reduce some causes of injuries and illnesses among firefighters, relatively little has been done to evaluate and understand occupational noise exposures in this group. The purpose of this pilot study was to apply a task-based noise exposure assessment methodology to firefighting operations to evaluate potential noise exposure sources, and to use collected task-based noise levels to create noise exposure estimates for evaluation of risk of noise-induced hearing loss by comparison to the 8-hr and 24-hr recommended exposure limits (RELs) for noise of 85 and 80.3 dBA, respectively.
Methods: Task-based noise exposures (n=100 measurements) were measured in three different fire departments (a rural department in Southeast Michigan and suburban and urban departments in Northern California). These levels were then combined with time-at-task information collected from firefighters to estimate 8-hr noise exposures for the rural and suburban fire departments (n=6 estimates for each department). Data from 24-hr dosimetry measurements and crude self-reported activity categories from the urban fire department (n=4 measurements) were used to create 24-hr exposure estimates to evaluate the bias associated with the task-based estimates.
Results: Task-based noise levels were found to range from 82-109 dBA, with the highest levels resulting from use of saws and pneumatic chisels. Some short (e.g., 30 min) sequences of common tasks were found to result in nearly an entire allowable daily exposure. The majority of estimated 8-hr and 24-hr exposures exceeded the relevant recommended exposure limit. Predicted 24-hr exposures showed substantial imprecision in some cases, suggesting the need for increased task specificity.
Conclusions: The results indicate potential for overexposure to noise from a variety of firefighting tasks and equipment, and suggest a need for further exposure characterization and additional hearing loss prevention efforts.
Relevance to industry: Firefighters may be at risk of noise-induced hearing loss, which can affect their fitness for duty and ability to respond effectively to emergencies. The results of this study suggest that additional efforts at hearing loss prevention among firefighters are warranted.
Keywords: Noise; emergency response; exposure; firefighter; hearing loss; task-based assessment.
Similar articles
-
Firefighter noise exposure during training activities and general equipment use.J Occup Environ Hyg. 2013;10(3):116-21. doi: 10.1080/15459624.2012.753023. J Occup Environ Hyg. 2013. PMID: 23339379
-
Monitoring Occupational Noise Exposure in Firefighters Using the Apple Watch.Int J Environ Res Public Health. 2023 Jan 28;20(3):2315. doi: 10.3390/ijerph20032315. Int J Environ Res Public Health. 2023. PMID: 36767682 Free PMC article.
-
Perception and attitudes of firefighters on noise exposure and hearing loss.J Occup Environ Hyg. 2008 Mar;5(3):210-5. doi: 10.1080/15459620701880659. J Occup Environ Hyg. 2008. PMID: 18213534
-
Hazardous decibels: hearing health of firefighters.AAOHN J. 2007 Aug;55(8):313-9. doi: 10.1177/216507990705500803. AAOHN J. 2007. PMID: 17847625 Review.
-
Firefighters' noise exposure: A literature review.Int Arch Otorhinolaryngol. 2013 Jan;17(1):80-4. doi: 10.7162/S1809-97772013000100014. Int Arch Otorhinolaryngol. 2013. PMID: 25991998 Free PMC article. Review.
Cited by
-
Injury Risk and Noise Exposure in Firefighter Training Operations.Ann Occup Hyg. 2016 May;60(4):405-20. doi: 10.1093/annhyg/mev088. Epub 2015 Dec 27. Ann Occup Hyg. 2016. PMID: 26712895 Free PMC article.
-
Exploring First Responders' Use and Perceptions on Continuous Health and Environmental Monitoring.Int J Environ Res Public Health. 2023 Mar 8;20(6):4787. doi: 10.3390/ijerph20064787. Int J Environ Res Public Health. 2023. PMID: 36981694 Free PMC article.
-
Twenty-four-hour work shifts, increased job demands, and elevated blood pressure in professional firefighters.Int Arch Occup Environ Health. 2016 Oct;89(7):1111-25. doi: 10.1007/s00420-016-1151-5. Epub 2016 Jul 1. Int Arch Occup Environ Health. 2016. PMID: 27368424 Free PMC article.
-
Prevalence of Hearing Loss and Perceptions of Hearing Health and Protection among Florida Firefighters.Int J Environ Res Public Health. 2023 Feb 21;20(5):3826. doi: 10.3390/ijerph20053826. Int J Environ Res Public Health. 2023. PMID: 36900832 Free PMC article.
References
-
- Arezes P, Bernardo C, et al. Measurement strategies for occupational noise exposure assessment: A comparison study in different industrial environments. Int J Indust Ergo. 2012;42(1):172–177.
-
- EASHW; E. A. f. S. a. H. a. Work. European risk observatory literature review: Combined exposure to noise and ototoxic substances. Luxembourg: Office for Official Publications of the European Communities; 2009.
-
- EPA. Information on levels of environmental noise requisite to protect public health and welfare with an adequate margin of safety. 1974. EPA Report 550/9-74-004.
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources