Reduction of perioperative hemorrhage by anterior mediastinal spray application of fibrin glue during cardiac operations
- PMID: 2445314
- DOI: 10.1016/s0003-4975(10)62115-7
Reduction of perioperative hemorrhage by anterior mediastinal spray application of fibrin glue during cardiac operations
Abstract
A variety of published techniques for the production of concentrated fibrinogen from units of screened single-donor human plasma have led to increasing clinical use of fibrin glue in the United States. We have adapted a method of applying this material with a disposable plastic sprayer. In 20 consecutively treated patients, fibrin glue was sprayed on the anterior mediastinum before closure of the median sternotomy incision. A control group of 20 patients undergoing the identical cardiac operations (13 coronary artery bypass grafting procedures [CABG], 4 valve replacements [including 1 reoperative procedure], and 3 combined valve replacements and CABG) by the same surgeon within a one-year period was chosen for comparison of chest tube outputs. Specifically, chest tube outputs were as follows for treated and untreated patients, respectively: at 12 hours, 461 +/- 40 ml (mean +/- 1 standard error of the mean versus 731 +/- 80 ml; at 24 hours, 714 +/- 73 ml versus 1,016 +/- 109 ml; and at 48 hours, 863 +/- 93 ml versus 1,187 +/- 137 ml. The differences between control and spray chest tube output are statistically significant by unpaired t test (p less than 0.05) at both 12 and 24 hours. Thus, this method can reduce perioperative hemorrhage from the anterior mediastinum after cardiac operations.
MeSH terms
Substances
LinkOut - more resources