Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Clinical Trial
. 2014 Jun;37(6):768-73.
doi: 10.1111/pace.12343. Epub 2014 Jan 23.

Psychological indices as predictors for phantom shocks in implantable cardioverter defibrillator recipients

Affiliations
Clinical Trial

Psychological indices as predictors for phantom shocks in implantable cardioverter defibrillator recipients

Annemieke Starrenburg et al. Pacing Clin Electrophysiol. 2014 Jun.

Abstract

Background: A phantom shock-the sensation of an implantable cardioverter defibrillator (ICD) discharge in the absence of an actual discharge-is a phenomenon that can occur in ICD patients. Little is known about the influence of psychological factors on the incidence of phantom shocks. We evaluated psychological correlates of phantom shocks 2 years post-ICD implant in a cohort of Dutch ICD recipients.

Methods: Consecutive patients (N = 300; 87.5% men; mean age = 62.3) willing to participate in a prospective study (Twente ICD Cohort Study) on psychological factors in ICD recipients received an ICD between September 2007 and February 2010. At baseline, patients complete the 36-item Short Form Health Survey, Hospital Anxiety and Depression Scale, and the Type D Scale. Lifetime presence of anxiety and depression was assessed with the MINI structural interview.

Results: During a follow-up of 24 months, 16 patients (5.4%) experienced a phantom shock. Median time to (first) phantom shock was 13 weeks (range 0-48 weeks). In univariable analysis, no significant relationships were found between clinical or psychological indices and the occurrence of phantom shocks, nor was there an association between phantom shocks and type D personality, symptoms of anxiety, or a history of anxiety and depression.

Conclusions: Neither symptoms of anxiety and depression nor psychiatric history were associated with the occurrence of phantom shocks. Further studies using more explorative, qualitative research techniques are warranted to examine the correlates of phantom shocks.

Keywords: anxiety; depression; implantable cardioverter defibrillators; phantom shocks.

PubMed Disclaimer

Similar articles

Cited by

Publication types

MeSH terms