Psychological indices as predictors for phantom shocks in implantable cardioverter defibrillator recipients
- PMID: 24456312
- DOI: 10.1111/pace.12343
Psychological indices as predictors for phantom shocks in implantable cardioverter defibrillator recipients
Abstract
Background: A phantom shock-the sensation of an implantable cardioverter defibrillator (ICD) discharge in the absence of an actual discharge-is a phenomenon that can occur in ICD patients. Little is known about the influence of psychological factors on the incidence of phantom shocks. We evaluated psychological correlates of phantom shocks 2 years post-ICD implant in a cohort of Dutch ICD recipients.
Methods: Consecutive patients (N = 300; 87.5% men; mean age = 62.3) willing to participate in a prospective study (Twente ICD Cohort Study) on psychological factors in ICD recipients received an ICD between September 2007 and February 2010. At baseline, patients complete the 36-item Short Form Health Survey, Hospital Anxiety and Depression Scale, and the Type D Scale. Lifetime presence of anxiety and depression was assessed with the MINI structural interview.
Results: During a follow-up of 24 months, 16 patients (5.4%) experienced a phantom shock. Median time to (first) phantom shock was 13 weeks (range 0-48 weeks). In univariable analysis, no significant relationships were found between clinical or psychological indices and the occurrence of phantom shocks, nor was there an association between phantom shocks and type D personality, symptoms of anxiety, or a history of anxiety and depression.
Conclusions: Neither symptoms of anxiety and depression nor psychiatric history were associated with the occurrence of phantom shocks. Further studies using more explorative, qualitative research techniques are warranted to examine the correlates of phantom shocks.
Keywords: anxiety; depression; implantable cardioverter defibrillators; phantom shocks.
©2014 Wiley Periodicals, Inc.
Similar articles
-
Shocks, personality, and anxiety in patients with an implantable defibrillator.Pacing Clin Electrophysiol. 2008 Jul;31(7):850-7. doi: 10.1111/j.1540-8159.2008.01099.x. Pacing Clin Electrophysiol. 2008. PMID: 18684282 Clinical Trial.
-
Psychological indices and phantom shocks in patients with ICD.J Interv Card Electrophysiol. 2006 Apr;15(3):185-90. doi: 10.1007/s10840-006-9010-z. Epub 2006 Aug 4. J Interv Card Electrophysiol. 2006. PMID: 17019638 Clinical Trial.
-
Monitoring device acceptance in implantable cardioverter defibrillator patients using the Florida Patient Acceptance Survey.Pacing Clin Electrophysiol. 2012 Mar;35(3):283-93. doi: 10.1111/j.1540-8159.2011.03299.x. Epub 2012 Jan 9. Pacing Clin Electrophysiol. 2012. PMID: 22229519
-
Anxiety and depression in implanted cardioverter-defibrillator recipients and heart failure: a review.Heart Fail Clin. 2011 Jan;7(1):59-68. doi: 10.1016/j.hfc.2010.08.008. Heart Fail Clin. 2011. PMID: 21109208 Review.
-
Psychological disturbances, adjustment, and the development of phantom shocks in patients with an implantable cardioverter defibrillator.J Cardiovasc Nurs. 2005 Jul-Aug;20(4):288-93. doi: 10.1097/00005082-200507000-00016. J Cardiovasc Nurs. 2005. PMID: 16000918 Review.
Cited by
-
Safety and efficiency of emergency department interrogation of cardiac devices.Clin Exp Emerg Med. 2016 Dec 30;3(4):239-244. doi: 10.15441/ceem.15.118. eCollection 2016 Dec. Clin Exp Emerg Med. 2016. PMID: 28168230 Free PMC article.
-
Incidence, Risk Factors and Predictors of Phantom Shocks in Patients with Implantable Cardioverter Defibrillators: State-of-the-art Review.Arrhythm Electrophysiol Rev. 2024 Nov 4;13:e18. doi: 10.15420/aer.2024.25. eCollection 2024. Arrhythm Electrophysiol Rev. 2024. PMID: 39569079 Free PMC article. Review.
-
Psychosocial symptoms of ventricular arrhythmias: Integrating patient-reported outcomes into clinical care.Heart Rhythm O2. 2021 Dec 17;2(6Part B):832-839. doi: 10.1016/j.hroo.2021.09.011. eCollection 2021 Dec. Heart Rhythm O2. 2021. PMID: 34988534 Free PMC article.
-
[Cardiac implantable electronic devices and health-related quality of life].Herzschrittmacherther Elektrophysiol. 2019 Jun;30(2):160-167. doi: 10.1007/s00399-019-0619-x. Epub 2019 Apr 10. Herzschrittmacherther Elektrophysiol. 2019. PMID: 30969354 Review. German.
-
Hospital Anxiety and Depression Scale Anxiety subscale (HADS-A) for detecting anxiety disorders in adults.Cochrane Database Syst Rev. 2025 Jul 2;7(7):CD015456. doi: 10.1002/14651858.CD015456. Cochrane Database Syst Rev. 2025. PMID: 40600405 Review.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical