Highly sensitive nonenzymatic glucose and H2O2 sensor based on Ni(OH)2/electroreduced graphene oxide--multiwalled carbon nanotube film modified glass carbon electrode
- PMID: 24468400
- DOI: 10.1016/j.talanta.2013.12.012
Highly sensitive nonenzymatic glucose and H2O2 sensor based on Ni(OH)2/electroreduced graphene oxide--multiwalled carbon nanotube film modified glass carbon electrode
Abstract
In this article, a nonenzymatic sensor based on Ni(OH)2/electroreduced graphene oxide (ERGO)-multiwalled carbon nanotube (MWNT) nanocomposites is fabricated via convenient electrodeposition of Ni(OH)2 nanoparticles on ERGO-MWNT film modified glass carbon electrode (GCE). Graphene oxide (GO) sheets can serve as surfactants to stabilize the dispersion of pristine MWNTs in aqueous solution, rendering a fine coverage of ERGO-MWNT film on GCE during the fabrication process. MWNTs perform as conducting bridges between ERGO sheets to enhance the electron transfer rate in the substrate. By combining the advantages of ERGO and MWNTs, together with electrocatalytic effect of Ni(OH)2 nanoparticles, the well-designed nanocomposites exhibit excellent sensing behavior towards glucose and hydrogen peroxide (H2O2). The linear detection ranges for glucose and H2O2 are 10-1500 µM and 10 µM-9050 µM while the detection limits are 2.7 µM and 4.0 µM, respectively. Furthermore, a very high sensitivity is achieved with 2042 µAm M(-1) cm(-2) estimated for glucose and 711 µAm M(-1) cm(-2) for H2O2. These results suggest that Ni(OH)2/ERGO-MWNT nanocomposites thus easily prepared through a green electrochemical method are promising electrode materials for biosensing. Additionally, good recoveries of analytes in real samples like urine and milk confirm the reliability of the prepared sensor in practical applications.
Keywords: Glucose sensor; Graphene; Hydrogen peroxide sensor; Multiwalled carbon nanotubes; Ni(OH)(2).
Copyright © 2013 Elsevier B.V. All rights reserved.
Similar articles
-
Fabrication of an electrochemical platform based on the self-assembly of graphene oxide-multiwall carbon nanotube nanocomposite and horseradish peroxidase: direct electrochemistry and electrocatalysis.Nanotechnology. 2011 Dec 9;22(49):494010. doi: 10.1088/0957-4484/22/49/494010. Epub 2011 Nov 21. Nanotechnology. 2011. PMID: 22101607
-
Direct electrochemistry of glucose oxidase at electrochemically reduced graphene oxide-multiwalled carbon nanotubes hybrid material modified electrode for glucose biosensor.Biosens Bioelectron. 2013 Mar 15;41:309-15. doi: 10.1016/j.bios.2012.08.045. Epub 2012 Aug 28. Biosens Bioelectron. 2013. PMID: 22964382
-
Hydrogen peroxide biosensor based on hemoglobin immobilized at graphene, flower-like zinc oxide, and gold nanoparticles nanocomposite modified glassy carbon electrode.Colloids Surf B Biointerfaces. 2013 Jul 1;107:245-50. doi: 10.1016/j.colsurfb.2013.02.020. Epub 2013 Feb 24. Colloids Surf B Biointerfaces. 2013. PMID: 23502047
-
Engineered Carbon-Nanomaterial-Based Electrochemical Sensors for Biomolecules.ACS Nano. 2016 Jan 26;10(1):46-80. doi: 10.1021/acsnano.5b05690. Epub 2015 Nov 30. ACS Nano. 2016. PMID: 26579616 Review.
-
Recent trends in carbon nanomaterial-based electrochemical sensors for biomolecules: A review.Anal Chim Acta. 2015 Aug 5;887:17-37. doi: 10.1016/j.aca.2015.05.049. Epub 2015 Jul 7. Anal Chim Acta. 2015. PMID: 26320782 Free PMC article. Review.
Cited by
-
Graphene- and Graphene Oxide-Based Nanocomposite Platforms for Electrochemical Biosensing Applications.Int J Mol Sci. 2019 Jun 18;20(12):2975. doi: 10.3390/ijms20122975. Int J Mol Sci. 2019. PMID: 31216691 Free PMC article. Review.
-
TiO2/MWCNT/Nafion-Modified Glassy Carbon Electrode as a Sensitive Voltammetric Sensor for the Determination of Hydrogen Peroxide.Sensors (Basel). 2023 Sep 7;23(18):7732. doi: 10.3390/s23187732. Sensors (Basel). 2023. PMID: 37765789 Free PMC article.
-
A review on graphene-based nanocomposites for electrochemical and fluorescent biosensors.RSC Adv. 2019 Mar 18;9(16):8778-8881. doi: 10.1039/c8ra09577a. eCollection 2019 Mar 15. RSC Adv. 2019. PMID: 35517682 Free PMC article. Review.
-
Copper/reduced graphene oxide film modified electrode for non-enzymatic glucose sensing application.Sci Rep. 2021 Apr 29;11(1):9302. doi: 10.1038/s41598-021-88747-x. Sci Rep. 2021. PMID: 33927300 Free PMC article.
-
In Vivo Detection of Glutamate in Tomatoes by an Enzyme-Based Electrochemical Biosensor.ACS Omega. 2022 Aug 16;7(34):30535-30542. doi: 10.1021/acsomega.2c04029. eCollection 2022 Aug 30. ACS Omega. 2022. PMID: 36061716 Free PMC article.