Clinical study in phase- contrast mammography: image-quality analysis
- PMID: 24470410
- DOI: 10.1098/rsta.2013.0025
Clinical study in phase- contrast mammography: image-quality analysis
Abstract
The first clinical study of phase-contrast mammography (PCM) with synchrotron radiation was carried out at the Synchrotron Radiation for Medical Physics beamline of the Elettra synchrotron radiation facility in Trieste (Italy) in 2006-2009. The study involved 71 patients with unresolved breast abnormalities after conventional digital mammography and ultrasonography exams carried out at the Radiology Department of Trieste University Hospital. These cases were referred for mammography at the synchrotron radiation facility, with images acquired using a propagation-based phase-contrast imaging technique. To investigate the contribution of phase-contrast effects to the image quality, two experienced radiologists specialized in mammography assessed the visibility of breast abnormalities and of breast glandular structures. The images acquired at the hospital and at the synchrotron radiation facility were compared and graded according to a relative seven-grade visual scoring system. The statistical analysis highlighted that PCM with synchrotron radiation depicts normal structures and abnormal findings with higher image quality with respect to conventional digital mammography.
Keywords: image quality; mammography; phase-contrast; synchrotron radiation.
Similar articles
-
Objective measurements of image quality in synchrotron radiation phase-contrast imaging versus digital mammography.Int J Comput Assist Radiol Surg. 2016 Feb;11(2):181-8. doi: 10.1007/s11548-015-1237-7. Epub 2015 Jun 20. Int J Comput Assist Radiol Surg. 2016. PMID: 26092659
-
First application of computed radiology to mammography with synchrotron radiation.Radiol Med. 2013 Feb;118(1):89-100. doi: 10.1007/s11547-012-0847-1. Epub 2012 Jun 28. Radiol Med. 2013. PMID: 22744351
-
A simplified edge illumination set-up for quantitative phase contrast mammography with synchrotron radiation at clinical doses.Phys Med Biol. 2015 Feb 7;60(3):N21-34. doi: 10.1088/0031-9155/60/3/N21. Epub 2015 Jan 9. Phys Med Biol. 2015. PMID: 25574755
-
The mammography project at the SYRMEP beamline.Eur J Radiol. 2008 Dec;68(3 Suppl):S58-62. doi: 10.1016/j.ejrad.2008.04.038. Epub 2008 Jul 9. Eur J Radiol. 2008. PMID: 18617344
-
[X-ray phase imaging using a X-ray tube with a small focal spot -improvement of image quality in mammography-].Igaku Butsuri. 2002;22(1):21-9. Igaku Butsuri. 2002. PMID: 12766293 Review. Japanese.
Cited by
-
Realistic wave-optics simulation of X-ray phase-contrast imaging at a human scale.Sci Rep. 2015 Jul 14;5:12011. doi: 10.1038/srep12011. Sci Rep. 2015. PMID: 26169570 Free PMC article.
-
Image quality comparison between a phase-contrast synchrotron radiation breast CT and a clinical breast CT: a phantom based study.Sci Rep. 2019 Nov 28;9(1):17778. doi: 10.1038/s41598-019-54131-z. Sci Rep. 2019. PMID: 31780707 Free PMC article.
-
Monochromatic breast computed tomography with synchrotron radiation: phase-contrast and phase-retrieved image comparison and full-volume reconstruction.J Med Imaging (Bellingham). 2019 Jul;6(3):031402. doi: 10.1117/1.JMI.6.3.031402. Epub 2018 Nov 27. J Med Imaging (Bellingham). 2019. PMID: 30525064 Free PMC article.
-
Low-density tissue scaffold imaging by synchrotron radiation propagation-based imaging computed tomography with helical acquisition mode.J Synchrotron Radiat. 2023 Mar 1;30(Pt 2):417-429. doi: 10.1107/S1600577523000772. Epub 2023 Feb 16. J Synchrotron Radiat. 2023. PMID: 36891855 Free PMC article.
-
Radiochromic film dosimetry in synchrotron radiation breast computed tomography: a phantom study.J Synchrotron Radiat. 2020 May 1;27(Pt 3):762-771. doi: 10.1107/S1600577520001745. Epub 2020 Apr 22. J Synchrotron Radiat. 2020. PMID: 32381779 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical