Meta-analysis of bioabsorbable versus durable polymer drug-eluting stents in 20,005 patients with coronary artery disease: an update
- PMID: 24478247
- DOI: 10.1002/ccd.25416
Meta-analysis of bioabsorbable versus durable polymer drug-eluting stents in 20,005 patients with coronary artery disease: an update
Abstract
Objectives: To perform an updated meta-analysis comparing biodegradable polymer drug eluting stents (BP-DES) and durable polymer drug eluting stents (DP-DES).
Background: BP-DES have been suggested to reduce late stent thrombosis (LST) rates as compared to first generation DP-DES. Recently, second generation DP-DES have replaced older DES, but comparison of these stents with BP-DES has not yielded consistent results.
Methods: Medline/Web databases were searched for studies comparing BP-DES and DP-DES, and reporting rates of overall/cardiac mortality, myocardial infarction (MI), LST, target lesion revascularization (TLR) and target vessel revascularization (TVR) and late lumen loss (LLL), with a follow-up ≥6 months.
Results: Twenty studies (20,005 patients) were included in the meta-analysis. Median follow-up time was 1 year. Compared with DP-DES, BP-DES showed lower LLL (in stent: weighted mean difference WMD -0.45 mm, 95% CI -0.66 to -0.24 mm, P = 0.00001; in segment: WMD -0.15 mm, 95% CI = -0.24 to -0.06 mm, P = 0.001) and lower rates of LST (OR 0.51, 95% CI = 0.30 to 0.86, P = 0.01), although they did not improve mortality, MI, TLR, and TVR rates. BP-DES coated with sirolimus or novolimus, in comparison with biolimus or paclitaxel, were associated with reduced LLL (P < 0.0001 for subgroups).
Conclusions: In comparison with DP-DES, BP-DES significantly reduce LLL and LST rates, without clear benefits on harder endpoints. The efficacy of BP-DES in preserving lumen patency seems larger for sirolimus and novolimus DES.
Keywords: angioplasty; bioabsorbable polymer; drug-eluting stent; meta-analysis; stent.
Copyright © 2014 Wiley Periodicals, Inc.
Similar articles
-
Biodegradable versus durable polymer drug eluting stents in coronary artery disease: insights from a meta-analysis of 5,834 patients.Eur J Prev Cardiol. 2014 Apr;21(4):411-24. doi: 10.1177/2047487312467745. Epub 2012 Nov 14. Eur J Prev Cardiol. 2014. PMID: 23152364 Review.
-
Improved safety and reduction in stent thrombosis associated with biodegradable polymer-based biolimus-eluting stents versus durable polymer-based sirolimus-eluting stents in patients with coronary artery disease: final 5-year report of the LEADERS (Limus Eluted From A Durable Versus ERodable Stent Coating) randomized, noninferiority trial.JACC Cardiovasc Interv. 2013 Aug;6(8):777-89. doi: 10.1016/j.jcin.2013.04.011. JACC Cardiovasc Interv. 2013. PMID: 23968698 Clinical Trial.
-
First-in-human evaluation of a bioabsorbable polymer-coated sirolimus-eluting stent: imaging and clinical results of the DESSOLVE I Trial (DES with sirolimus and a bioabsorbable polymer for the treatment of patients with de novo lesion in the native coronary arteries).JACC Cardiovasc Interv. 2013 Oct;6(10):1026-34. doi: 10.1016/j.jcin.2013.05.013. Epub 2013 Sep 18. JACC Cardiovasc Interv. 2013. PMID: 24055443 Clinical Trial.
-
5-year results of a randomized comparison of XIENCE V everolimus-eluting and TAXUS paclitaxel-eluting stents: final results from the SPIRIT III trial (clinical evaluation of the XIENCE V everolimus eluting coronary stent system in the treatment of patients with de novo native coronary artery lesions).JACC Cardiovasc Interv. 2013 Dec;6(12):1263-6. doi: 10.1016/j.jcin.2013.07.009. Epub 2013 Nov 13. JACC Cardiovasc Interv. 2013. PMID: 24239202 Clinical Trial.
-
Meta-Analysis of Randomized Clinical Trials Comparing Biodegradable Polymer Drug-Eluting Stent to Second-Generation Durable Polymer Drug-Eluting Stents.JACC Cardiovasc Interv. 2017 Mar 13;10(5):462-473. doi: 10.1016/j.jcin.2016.12.002. JACC Cardiovasc Interv. 2017. PMID: 28279314 Review.
Cited by
-
A Narrative Review of Ultrathin-strut Drug-eluting Stents: The Thinner the Better?Heart Int. 2021 Dec 21;15(2):84-93. doi: 10.17925/HI.2021.15.2.84. eCollection 2021. Heart Int. 2021. PMID: 36277831 Free PMC article. Review.
-
Short-term healing response after implantation of the thin-strut, fast-releasing sirolimus-eluting biodegradable polymer-coated Alex Plus stent: optical coherence tomography study.Postepy Kardiol Interwencyjnej. 2020 Jun;16(2):187-191. doi: 10.5114/aic.2020.96062. Epub 2020 Jun 23. Postepy Kardiol Interwencyjnej. 2020. PMID: 32636904 Free PMC article. No abstract available.
-
Real-World Experience With a Tapered Biodegradable Polymer-Coated Sirolimus-Eluting Stent in Patients With Long Coronary Artery Stenoses.Cardiol Res. 2020 Aug;11(4):219-225. doi: 10.14740/cr1055. Epub 2020 Jun 3. Cardiol Res. 2020. PMID: 32595806 Free PMC article.
-
Third generation drug eluting stent (DES) with biodegradable polymer in diabetic patients: 5 years follow-up.Cardiovasc Diabetol. 2017 Feb 10;16(1):23. doi: 10.1186/s12933-017-0500-3. Cardiovasc Diabetol. 2017. PMID: 28183306 Free PMC article.
-
Safety and Efficacy of Post-Dilation in Percutaneous Coronary Intervention Using Polymer-Free Ultrathin Strut Sirolimus-Probucol Coated Drug-Eluting Stents.Medicina (Kaunas). 2023 Sep 12;59(9):1649. doi: 10.3390/medicina59091649. Medicina (Kaunas). 2023. PMID: 37763768 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical