Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Controlled Clinical Trial
. 2014 Jun;46(6):1248-60.
doi: 10.1249/MSS.0000000000000214.

Reliability and validity of a domain-specific last 7-d sedentary time questionnaire

Affiliations
Controlled Clinical Trial

Reliability and validity of a domain-specific last 7-d sedentary time questionnaire

Katrien Wijndaele et al. Med Sci Sports Exerc. 2014 Jun.

Erratum in

  • Med Sci Sports Exerc. 2014 Sep;46(9):1869

Abstract

Purpose: The objective of this study is to examine test-retest reliability, criterion validity, and absolute agreement of a self-report, last 7-d sedentary behavior questionnaire (SIT-Q-7d), which assesses total daily sedentary time as an aggregate of sitting/lying down in five domains (meals, transportation, occupation, nonoccupational screen time, and other sedentary time). Dutch (DQ) and English (EQ) versions of the questionnaire were examined.

Methods: Fifty-one Flemish adults (ages 39.4 ± 11.1 yr) wore a thigh accelerometer (activPAL3™) and simultaneously kept a domain log for 7 d. The DQ was subsequently completed twice (median test-retest interval: 3.3 wk). Thigh-acceleration sedentary time was log annotated to create comparable domain-specific and total sedentary time variables. Four hundred two English adults (ages 49.6 ± 7.3 yr) wore a combined accelerometer and HR monitor (Actiheart) for 6 d to objectively measure total sedentary time. The EQ was subsequently completed twice (median test-retest interval: 3.4 wk). In both samples, the questionnaire reference frame overlapped with the criterion measure administration period. All participants had five or more valid days of criterion data, including one or more weekend day.

Results: Test-retest reliability (intraclass correlation coefficient (95% CI)) was fair to good for total sedentary time (DQ: 0.68 (0.50-0.81); EQ: 0.53 (0.44-0.62)) and poor to excellent for domain-specific sedentary time (DQ: from 0.36 (0.10-0.57) (meals) to 0.66 (0.46-0.79) (occupation); EQ: from 0.45 (0.35-0.54) (other sedentary time) to 0.76 (0.71-0.81) (meals)). For criterion validity (Spearman rho), significant correlations were found for total sedentary time (DQ: 0.52; EQ: 0.22; all P <0.001). Compared with domain-specific criterion variables (DQ), modest-to-strong correlations were found for domain-specific sedentary time (from 0.21 (meals) to 0.76 (P < 0.001) (screen time)). The questionnaire generally overestimated sedentary time compared with criterion measures.

Conclusion: The SIT-Q-7d appears to be a useful tool for ranking individuals in large-scale observational studies examining total and domain-specific sitting.

PubMed Disclaimer

Figures

FIGURE 1
FIGURE 1
Bland–Altman plot of absolute agreement of total sedentary time, occupational sedentary time, screen sedentary time, and sleep time derived from the questionnaire, with the equivalent variable derived from the criterion measure (combination of the thigh accelerometry and domainlog).
FIGURE 2
FIGURE 2
Bland–Altman plot of absolute agreement of total sedentary time derived from the questionnaire with the total sedentary time derived from the criterion measure (combined HR and trunk acceleration sensing).

References

    1. Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986; 1 (8476): 307– 10. - PubMed
    1. Bouchard C, Tremblay A, Leblanc C, Lortie G, Savard R, Theriault G. A method to assess energy expenditure in children and adults. Am J Clin Nutr. 1983; 37 (3): 461– 7. - PubMed
    1. Brage S, Brage N, Franks PW, Ekelund U, Wareham NJ. Reliability and validity of the combined heart rate and movement sensor Actiheart. Eur J Clin Nutr. 2005; 59 (4): 561– 70. - PubMed
    1. Brage S, Brage N, Franks PW, et al. Branched equation modeling of simultaneous accelerometry and heart rate monitoring improves estimate of directly measured physical activity energy expenditure. J Appl Physiol. 2004; 96 (1): 343– 51. - PubMed
    1. Brage S, Ekelund U, Brage N, et al. Hierarchy of individual calibration levels for heart rate and accelerometry to measure physical activity. J Appl Physiol. 2007; 103 (2): 682– 92. - PubMed

Publication types

Associated data