Accuracy of the Kato-Katz method and formalin-ether concentration technique for the diagnosis of Clonorchis sinensis, and implication for assessing drug efficacy
- PMID: 24499644
- PMCID: PMC3816101
- DOI: 10.1186/1756-3305-6-314
Accuracy of the Kato-Katz method and formalin-ether concentration technique for the diagnosis of Clonorchis sinensis, and implication for assessing drug efficacy
Abstract
Background: Clonorchiasis is a chronic neglected disease caused by a liver fluke, Clonorchis sinensis. Chemotherapy is the mainstay of control and treatment efficacy is usually determined by microscopic examination of fecal samples. We assessed the diagnostic accuracy of the Kato-Katz method and the formalin-ether concentration technique (FECT) for C. sinensis diagnosis, and studied the effect of diagnostic approach on drug efficacy evaluation.
Methods: Overall, 74 individuals aged ≥18 years with a parasitological confirmed C. sinensis infection at baseline were re-examined 3 weeks after treatment. Before and after treatment, two stool samples were obtained from each participant and each sample was subjected to triplicate Kato-Katz thick smears and a single FECT examination.
Results: Thirty-eight individuals were still positive for C. sinensis according to our diagnostic 'gold' standard (six Kato-Katz thick smears plus two FECT). Two FECT had a significantly lower sensitivity than six Kato-Katz thick smears (44.7% versus 92.1%; p <0.001). Examination of single Kato-Katz and single FECT considerably overestimated cure rates.
Conclusions: In settings where molecular diagnostic assays are absent, multiple Kato-Katz thick smears should be examined for an accurate diagnosis of C. sinensis infection and for assessing drug efficacy against this liver fluke infection.
Similar articles
-
Improving diagnostic performance of the Kato-Katz method for Clonorchis sinensis infection through multiple samples.Parasit Vectors. 2019 Jul 8;12(1):336. doi: 10.1186/s13071-019-3594-5. Parasit Vectors. 2019. PMID: 31287026 Free PMC article.
-
Comparison of the Kato-Katz method and ether-concentration technique for the diagnosis of soil-transmitted helminth infections in the framework of a randomised controlled trial.Eur J Clin Microbiol Infect Dis. 2014 May;33(5):815-22. doi: 10.1007/s10096-013-2019-1. Epub 2013 Nov 23. Eur J Clin Microbiol Infect Dis. 2014. PMID: 24272064
-
Accuracy of urine circulating cathodic antigen test for the diagnosis of Schistosoma mansoni in preschool-aged children before and after treatment.PLoS Negl Trop Dis. 2013;7(3):e2109. doi: 10.1371/journal.pntd.0002109. Epub 2013 Mar 21. PLoS Negl Trop Dis. 2013. PMID: 23556011 Free PMC article.
-
Current status of Clonorchis sinensis and clonorchiasis in China.Trans R Soc Trop Med Hyg. 2016 Jan;110(1):21-7. doi: 10.1093/trstmh/trv100. Trans R Soc Trop Med Hyg. 2016. PMID: 26740359 Review.
-
Clonorchiasis.Lancet. 2016 Feb 20;387(10020):800-10. doi: 10.1016/S0140-6736(15)60313-0. Epub 2015 Aug 21. Lancet. 2016. PMID: 26299184 Review.
Cited by
-
Performance evaluation of existing immunoassays for Clonorchis sinensis infection in China.Parasit Vectors. 2018 Jan 15;11(1):35. doi: 10.1186/s13071-018-2612-3. Parasit Vectors. 2018. PMID: 29334990 Free PMC article.
-
Pathological Lesions and Inducible Nitric Oxide Synthase Expressions in the Liver of Mice Experimentally Infected with Clonorchis sinensis.Korean J Parasitol. 2015 Dec;53(6):777-83. doi: 10.3347/kjp.2015.53.6.777. Epub 2015 Dec 31. Korean J Parasitol. 2015. PMID: 26797449 Free PMC article.
-
Current status and perspectives of Clonorchis sinensis and clonorchiasis: epidemiology, pathogenesis, omics, prevention and control.Infect Dis Poverty. 2016 Jul 6;5(1):71. doi: 10.1186/s40249-016-0166-1. Infect Dis Poverty. 2016. PMID: 27384714 Free PMC article. Review.
-
Improving diagnostic performance of the Kato-Katz method for Clonorchis sinensis infection through multiple samples.Parasit Vectors. 2019 Jul 8;12(1):336. doi: 10.1186/s13071-019-3594-5. Parasit Vectors. 2019. PMID: 31287026 Free PMC article.
-
Additional Evaluation of the Point-of-Contact Circulating Cathodic Antigen Assay for Schistosoma mansoni Infection.Front Public Health. 2015 Mar 19;3:48. doi: 10.3389/fpubh.2015.00048. eCollection 2015. Front Public Health. 2015. PMID: 25853117 Free PMC article.
References
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical