[Photography of anterior eye segment and fundus with smartphone]
- PMID: 24505930
[Photography of anterior eye segment and fundus with smartphone]
Abstract
Purpose: To evaluate the safety and efficacy of anterior segment and fundus photography with a smartphone (iPhone 4S).
Method: Safety was evaluated by comparing the luminance of the light emitting diode (LED) of the iPhone 4S and of a binocular indirect ophthalmoscope. Efficacy was assessed by recording the ocular findings in patients. The anterior segment was photographed in 30 patients using a macro lens and a handy slit lamp as a light source, and the retinal image was captured in 60 patients using a fundus lens.
Result: The luminance of the iPhone LED was approximately 700,000 cd/m2, apparently lower than that of the ophthalmoscope, approximately 1,400,000 cd/m2. Clear images of the anterior segment were captured in all cases, and the fundus was clearly photographed in 58 of 60 cases. It was possible to watch the display and evaluate the real time images with other practitioners.
Conclusion: We could successfully record and share the images of the anterior segment and fundus recorded with a smartphone. The current method is useful for diagnosis, treatment, and education in ophthalmology.
Similar articles
-
[Technical Options of Documentation of the Anterior Segment and the eye Fundus Findings within Mission].Cesk Slov Oftalmol. 2016 Fall;72(3):86-90. Cesk Slov Oftalmol. 2016. PMID: 27658976 Czech.
-
Comparing smartphone camera adapters in imaging post-operative cataract patients.J Telemed Telecare. 2017 Jan;23(1):36-43. doi: 10.1177/1357633X15625400. Epub 2016 Jul 9. J Telemed Telecare. 2017. PMID: 26851243
-
Fundus photography with a smartphone in indirect ophthalmoscopy in dogs and cats.Vet Ophthalmol. 2017 May;20(3):280-284. doi: 10.1111/vop.12399. Epub 2016 Jun 15. Vet Ophthalmol. 2017. PMID: 27302683
-
Anterior segment imaging in pediatric ophthalmology.J Cataract Refract Surg. 2011 Dec;37(12):2201-10. doi: 10.1016/j.jcrs.2011.09.026. J Cataract Refract Surg. 2011. PMID: 22108115 Review.
-
Photography of the anterior eye segment according to Scheimpflug's principle: options and limitations - a review.Clin Exp Ophthalmol. 2009 Jan;37(1):144-54. doi: 10.1111/j.1442-9071.2009.02018.x. Clin Exp Ophthalmol. 2009. PMID: 19338611 Review.
Cited by
-
A Smartphone-Based Tool for Rapid, Portable, and Automated Wide-Field Retinal Imaging.Transl Vis Sci Technol. 2018 Oct 1;7(5):21. doi: 10.1167/tvst.7.5.21. eCollection 2018 Sep. Transl Vis Sci Technol. 2018. PMID: 30280006 Free PMC article.
-
Physician, patient, and caregiver experience of different wet age-related macular degeneration anti-VEGF treatment regimens in Japan: a qualitative assessment.Clin Ophthalmol. 2016 Dec 15;10:2505-2513. doi: 10.2147/OPTH.S120803. eCollection 2016. Clin Ophthalmol. 2016. PMID: 28008223 Free PMC article.
-
Cost-effectiveness of Different Diabetic Retinopathy Screening Modalities.J Diabetes Sci Technol. 2015 Dec 29;10(2):301-7. doi: 10.1177/1932296815624109. J Diabetes Sci Technol. 2015. PMID: 26719134 Free PMC article.
-
The Use of Smart phones in Ophthalmology.Acta Inform Med. 2014 Jun;22(3):206-9. doi: 10.5455/aim.2014.22.206-209. Epub 2014 Jun 15. Acta Inform Med. 2014. PMID: 25132717 Free PMC article. Review.
-
Agreement between retinal images obtained via smartphones and images obtained with retinal cameras or fundoscopic exams - systematic review and meta-analysis.Clin Ophthalmol. 2018 Dec 11;12:2581-2589. doi: 10.2147/OPTH.S182022. eCollection 2018. Clin Ophthalmol. 2018. PMID: 30587904 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources