Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2014 Apr;56(4):291-5.
doi: 10.1007/s00234-014-1333-3. Epub 2014 Feb 8.

Dual-energy CT for detection of contrast enhancement or leakage within high-density haematomas in patients with intracranial haemorrhage

Affiliations

Dual-energy CT for detection of contrast enhancement or leakage within high-density haematomas in patients with intracranial haemorrhage

Yoshiyuki Watanabe et al. Neuroradiology. 2014 Apr.

Abstract

Introduction: Our study aimed to elucidate the diagnostic performance of dual-energy CT (DECT) in the detection of contrast enhancement in intracranial haematomas (ICrH) with early phase dual-energy computed tomography angiography (CTA) and compare the results with those obtained by delayed CT enhancement.

Methods: Thirty-six patients with ICrH were retrospectively included in this study. All patients had undergone single-energy non-contrast CT and contrast-enhanced dual-source DECT. DECT images were post-processed with commercial software, followed by obtaining iodine images and virtual non-contrast images and generating combined images that created the impression of 120-kVp images. Two neuroradiologists, blinded to the patients' data, reviewed two reading sessions: session A (non-contrast CT and combined CT) and session B (non-contrast CT, combined CT, and iodine images) for detection of contrast enhancement in the haematomas.

Results: Contrast leakage or enhancement was detected in 23 (57.5 %) out of 40 haemorrhagic lesions in 36 patients on delayed CT. Three enhanced lesions were depicted only in the DECT iodine images. The sensitivity, specificity, positive predictive value, and negative predictive value of session A were 82.6, 94.1, 95.0, and 80.0 %, respectively, and those of session B were 95.7, 94.1, 95.7, and 94.1 %, respectively.

Conclusion: DECT emphasised the iodine enhancement and facilitated the detection of contrast enhancement or leakage.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Radiology. 2010 Oct;257(1):205-11 - PubMed
    1. AJNR Am J Neuroradiol. 2012 Jun;33(6):1088-94 - PubMed
    1. J Korean Neurosurg Soc. 2010 Nov;48(5):399-405 - PubMed
    1. Stroke. 2009 May;40(5):1672-6 - PubMed
    1. Clin Neurol Neurosurg. 2010 Oct;112(8):737-9 - PubMed

MeSH terms

LinkOut - more resources