Dual-energy CT for detection of contrast enhancement or leakage within high-density haematomas in patients with intracranial haemorrhage
- PMID: 24510167
- DOI: 10.1007/s00234-014-1333-3
Dual-energy CT for detection of contrast enhancement or leakage within high-density haematomas in patients with intracranial haemorrhage
Abstract
Introduction: Our study aimed to elucidate the diagnostic performance of dual-energy CT (DECT) in the detection of contrast enhancement in intracranial haematomas (ICrH) with early phase dual-energy computed tomography angiography (CTA) and compare the results with those obtained by delayed CT enhancement.
Methods: Thirty-six patients with ICrH were retrospectively included in this study. All patients had undergone single-energy non-contrast CT and contrast-enhanced dual-source DECT. DECT images were post-processed with commercial software, followed by obtaining iodine images and virtual non-contrast images and generating combined images that created the impression of 120-kVp images. Two neuroradiologists, blinded to the patients' data, reviewed two reading sessions: session A (non-contrast CT and combined CT) and session B (non-contrast CT, combined CT, and iodine images) for detection of contrast enhancement in the haematomas.
Results: Contrast leakage or enhancement was detected in 23 (57.5 %) out of 40 haemorrhagic lesions in 36 patients on delayed CT. Three enhanced lesions were depicted only in the DECT iodine images. The sensitivity, specificity, positive predictive value, and negative predictive value of session A were 82.6, 94.1, 95.0, and 80.0 %, respectively, and those of session B were 95.7, 94.1, 95.7, and 94.1 %, respectively.
Conclusion: DECT emphasised the iodine enhancement and facilitated the detection of contrast enhancement or leakage.
Similar articles
-
Dual-energy CT of the brain: Comparison between DECT angiography-derived virtual unenhanced images and true unenhanced images in the detection of intracranial haemorrhage.Eur Radiol. 2017 Jul;27(7):2690-2697. doi: 10.1007/s00330-016-4658-y. Epub 2016 Nov 23. Eur Radiol. 2017. PMID: 27882426
-
Detecting Intracranial Hemorrhage Using Automatic Tube Current Modulation With Advanced Modeled Iterative Reconstruction in Unenhanced Head Single- and Dual-Energy Dual-Source CT.AJR Am J Roentgenol. 2017 May;208(5):1089-1096. doi: 10.2214/AJR.16.17171. Epub 2017 Feb 28. AJR Am J Roentgenol. 2017. PMID: 28245141
-
Rapid switching kVp dual energy CT: Value of reconstructed dual energy CT images and organ dose assessment in multiphasic liver CT exams.Eur J Radiol. 2018 May;102:102-108. doi: 10.1016/j.ejrad.2018.02.022. Epub 2018 Feb 19. Eur J Radiol. 2018. PMID: 29685522 Free PMC article.
-
Dual-energy CT revisited with multidetector CT: review of principles and clinical applications.Diagn Interv Radiol. 2011 Sep;17(3):181-94. doi: 10.4261/1305-3825.DIR.3860-10.0. Epub 2010 Nov 14. Diagn Interv Radiol. 2011. PMID: 20945292 Review.
-
Dual-energy CT for differentiating acute intracranial hemorrhage from contrast staining or calcification: a meta-analysis.Neuroradiology. 2020 Dec;62(12):1617-1626. doi: 10.1007/s00234-020-02486-w. Epub 2020 Jul 4. Neuroradiology. 2020. PMID: 32621024
Cited by
-
Use of dual-energy computed tomography post endovascular treatment of cerebral aneurysm.Surg Neurol Int. 2021 May 17;12:225. doi: 10.25259/SNI_41_2021. eCollection 2021. Surg Neurol Int. 2021. PMID: 34221556 Free PMC article.
-
Phantom-based standardization of CT angiography images for spot sign detection.Neuroradiology. 2017 Sep;59(9):839-844. doi: 10.1007/s00234-017-1857-4. Epub 2017 Jul 20. Neuroradiology. 2017. PMID: 28730267 Free PMC article.
-
Principles and Clinical Application of Dual-energy Computed Tomography in the Evaluation of Cerebrovascular Disease.J Clin Imaging Sci. 2016 Jun 29;6:27. doi: 10.4103/2156-7514.185003. eCollection 2016. J Clin Imaging Sci. 2016. PMID: 27512615 Free PMC article. Review.
-
Dual-energy CT of the brain: Comparison between DECT angiography-derived virtual unenhanced images and true unenhanced images in the detection of intracranial haemorrhage.Eur Radiol. 2017 Jul;27(7):2690-2697. doi: 10.1007/s00330-016-4658-y. Epub 2016 Nov 23. Eur Radiol. 2017. PMID: 27882426
-
Clinical utility of consecutive volume scanning dual-energy CT in differentiating hemorrhage from contrast staining in ischemic stroke patients.J Appl Clin Med Phys. 2025 Sep;26(9):e70209. doi: 10.1002/acm2.70209. J Appl Clin Med Phys. 2025. PMID: 40841276 Free PMC article.
References
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical