. 2014 Feb;11(2):175-81.
doi: 10.1016/j.hrthm.2013.10.042.

Localizing the critical isthmus of postinfarct ventricular tachycardia: the value of pace-mapping during sinus rhythm

Localizing the critical isthmus of postinfarct ventricular tachycardia: the value of pace-mapping during sinus rhythm

Christian de Chillou et al. Heart Rhythm. 2014 Feb.

Abstract

Background: Most postinfarct ventricular tachycardias (VTs) are sustained by a reentrant mechanism. The "protected isthmus" of the reentrant circuit is critical for the maintenance of VTs and the target for catheter ablation. Various techniques based on conventional electrophysiology and/or detailed three-dimensional (3D) reconstruction of the VT circuit are used to unmask this isthmus.

Objective: The purpose of this study was to assess pace-maps (PMs) to identify postinfarct VT isthmuses. We hypothesized that an abrupt change in paced QRS morphology may be used to identify a VT isthmus and be targeted for successful ablation.

Methods: High-density 3D PMs were matched to the subsequent 3D endocardial reentrant VT activation mapping in 10 patients (8 men; age 70.7 ± 10.8 years) who underwent successful postinfarct VT ablation. At each pacing site in a given patient, the 12-lead ECG recorded during pacing was compared to that of VT, with the resulting matching percentage (up to 100% for perfect matches) allocated to this point to generate color-coded PMs.

Results: With respect to VT isthmuses, the best percentages of matching were found in the exit zones and isthmus exit part (89% ± 8% and 84% ± 7%, respectively) and the poorest adjacent to scar border in the outer entrance zones (23% ± 28%), in the entrance zones (39% ± 34%), and in the entrance part of the isthmus (32% ± 26%). The color-coded sequence (from the best to the poorest matching sites) on the PMs revealed figure-of-eight pictures matching the VT activation time maps and identifying VT isthmuses.

Conclusion: Pace-mapping is useful for unmasking VT isthmuses in patients with well-tolerated postinfarct endocardial reentrant VTs.

PubMed Disclaimer