Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Randomized Controlled Trial
. 2014 Aug;20(8):785-91.
doi: 10.4158/EP13411.OR.

Efficacy and Safety of Insulin Degludec 200 U/mL and Insulin Degludec 100 U/mL in Patients with Type 2 Diabetes (Begin: Compare)

Affiliations
Randomized Controlled Trial

Efficacy and Safety of Insulin Degludec 200 U/mL and Insulin Degludec 100 U/mL in Patients with Type 2 Diabetes (Begin: Compare)

Bruce W Bode et al. Endocr Pract. 2014 Aug.

Abstract

Objective: The purpose of the present study was to provide clinical data on the efficacy and safety of insulin degludec (IDeg) 200 U/mL compared with IDeg 100 U/mL in patients with type 2 diabetes mellitus (T2DM) currently treated with basal insulin in combination with oral antidiabetic drugs.

Methods: In this 22-week, treat-to-target trial, eligible adult patients with T2DM were randomized 1:1 to IDeg 200 or IDeg 100 U/mL once daily (OD) (n = 186 and 187, respectively). The starting insulin dose was based on a 1:1 transfer of the total prerandomization basal insulin dose. The primary endpoint was change (%) from baseline in glycosylated hemoglobin A1C (A1C) after 22 weeks of treatment.

Results: A total of 373 subjects (mean age 59.8 years, A1C 8.2%, fasting plasma glucose 149.6 mg/dL [8.3 mmol/L], body mass index 33.3 kg/m2) were randomized. A1C reduction with IDeg 200 U/mL was noninferior to that of IDeg 100 U/mL (IDeg 200 U/mL - IDeg 100 U/mL estimated treatment difference: -0.11%, 95% confidence interval (CI): -0.28 to 0.05). Rates of overall confirmed hypoglycemia were low and similar between both formulations (5.17 and 5.66 events/patient-year of exposure [PYE] for IDeg 200 and 100 U/mL, respectively). Similarly, the rates of nocturnal confirmed hypoglycemia were low (1.27 and 1.70 events/PYE for 200 and 100 U/mL). In general, both IDeg formulations were well tolerated (respective rates of adverse events: 4.16 and 3.00 events/PYE for 200 and 100 U/mL).

Conclusion: The 200 and 100 U/mL formulations of IDeg provide comparable and effective levels of glycemic control with similar, low rates of overall confirmed and nocturnal confirmed hypoglycemia.

PubMed Disclaimer

Publication types

LinkOut - more resources