Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2014 May;25(5):685-692.e5.
doi: 10.1016/j.jvir.2013.12.012. Epub 2014 Feb 12.

Secondary procedures following thoracic aortic stent grafting in the first 3 years of the VALOR test and VALOR II trials

Affiliations
Comparative Study

Secondary procedures following thoracic aortic stent grafting in the first 3 years of the VALOR test and VALOR II trials

Alan H Matsumoto et al. J Vasc Interv Radiol. 2014 May.

Abstract

Purpose: To compare the durability of thoracic endovascular aortic repair (TEVAR) in two similar clinical trials that used early- and later-generation stent grafts.

Materials and methods: Secondary procedures from the prospective, nonrandomized, multicenter, clinical trial databases of the test arm of the VALOR and VALOR II trials were analyzed at 3 years. Descriptive and statistical analyses were employed to compare the rate of and potential predictors for secondary procedures.

Results: A total of 127 and 96 patients were available for a minimum of 3 years of follow-up in the test arm of VALOR and VALOR II, respectively. By the first year after the index procedure, VALOR II patients were significantly less likely to have undergone a secondary procedure versus patients in the test arm of VALOR (odds ratio [OR], 0.08; 95% confidence interval [CI], 0.01-0.63; P = .02), with most procedures performed for type I endoleak. Multivariate predictors at 3 years for the need for a secondary procedure in the VALOR test arm were maximum aneurysm diameter (P = .002) and aneurysm length (P = .01), both of which remained significant at the end of the study period. The estimated freedoms from secondary procedures in the VALOR test arm and VALOR II at 3 years were 85.1% (95% CI, 78.5%-89.8%) and 94.9% (95% CI, 88.8%-97.7%), respectively (P < .001).

Conclusions: The rate of secondary procedures after TEVAR differed between the two cohorts, being substantially lower in the VALOR II trial at 1 year of follow-up. This finding suggests significant benefit from advances in some combination of operator experience, imaging systems, treatment planning, and device design.

PubMed Disclaimer

Publication types