Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Review
. 2014 Feb 15;10(2):215-27.
doi: 10.5664/jcsm.3460.

Oral appliance treatment for obstructive sleep apnea: an update

Affiliations
Review

Oral appliance treatment for obstructive sleep apnea: an update

Kate Sutherland et al. J Clin Sleep Med. .

Abstract

Oral appliances (OA) have emerged as an alternative to continuous positive airway pressure (CPAP) for obstructive sleep apnea (OSA) treatment. The most commonly used OA reduces upper airway collapse by advancing the mandible (OAm). There is a strong evidence base demonstrating OAm improve OSA in the majority of patients, including some with more severe disease. However OAm are not efficacious for all, with approximately one-third of patients experiencing no therapeutic benefit. OAm are generally well tolerated, although short-term adverse effects during acclimatization are common. Long-term dental changes do occur, but these are for the most part subclinical and do not preclude continued use. Patients often prefer OAm to gold-standard CPAP treatment. Head-to-head trials confirm CPAP is superior in reducing OSA parameters on polysomnography; however, this greater efficacy does not necessarily translate into better health outcomes in clinical practice. Comparable effectiveness of OAm and CPAP has been attributed to higher reported nightly use of OAm, suggesting that inferiority in reducing apneic events may be counteracted by greater treatment adherence. Recently, significant advances in commercially available OAm technologies have been made. Remotely controlled mandibular positioners have the potential to identify treatment responders and the level of therapeutic advancement required in single night titration polysomnography. Objective monitoring of OAm adherence using small embedded temperature sensing data loggers is now available and will enhance clinical practice and research. These technologies will further enhance efficacy and effectiveness of OAm treatment for OSA.

Keywords: Obstructive sleep apnea; adherence; effectiveness; mandibular advancement; oral appliance.

PubMed Disclaimer

References

    1. Young T, Palta M, Dempsey J, Skatrud J, Weber S, Badr S. The occurrence of sleep-disordered breathing among middle-aged adults. N Engl J Med. 1993;328:1230–5. - PubMed
    1. Marshall NS, Wong KK, Liu PY, Cullen SR, Knuiman MW, Grunstein RR. Sleep apnea as an independent risk factor for all-cause mortality: the Busselton Health Study. Sleep. 2008;31:1079–85. - PMC - PubMed
    1. Young T, Peppard PE, Gottlieb DJ. Epidemiology of obstructive sleep apnea: a population health perspective. Am J Respir Crit Care Med. 2002;165:1217–39. - PubMed
    1. Kribbs NB, Pack AI, Kline LR, et al. Objective measurement of patterns of nasal CPAP use by patients with obstructive sleep apnea. Am Rev Respir Dis. 1993;147:887–95. - PubMed
    1. Chan ASL, Sutherland K, Schwab RJ, et al. The effect of mandibular advancement on upper airway structure in obstructive sleep apnoea. Thorax. 2010;65:726–32. - PubMed

Publication types

MeSH terms