Improved efficacy of intra-aortic balloon pumping by pharmacological myocardial protection for postoperative pump failure after coronary revascularization
- PMID: 2455089
- DOI: 10.1007/BF02470848
Improved efficacy of intra-aortic balloon pumping by pharmacological myocardial protection for postoperative pump failure after coronary revascularization
Abstract
Fifty patients took part in a randomized and prospective study to define the effect of pharmacological myocardial protection when using IABP in patients with postoperative pump failure, following coronary revascularization under cardiopulmonary bypass employing moderate hypothermia and cardioplegia. Pharmacological protection was given to 23 patients, administering coenzyme Q, 5 mg/kg, and aprotinin, 10,000 KIU/kg, intravenously, every 12 hours, following surgery. A single dose of each drug was also given intraoperatively. The postoperative haemodynamics, serum enzyme levels and success of weaning from IABP, were compared between the group of patients who received pharmacological protection (the treated group) and the control group which comprised 27 patients who were treated only with IABP. Among the surviving patients, no significant differences were seen in the hemodynamics or cardiac enzyme levels between the two groups. The rate of successful weaning from IABP however, was 95 per cent in the treated group as compared with only 74 per cent in the control group, p = 0.02. These results suggest that pharmacological myocardial protection, using coenzyme Q and aprotinin in both the intra- and post-operative periods, improves the efficacy of IABP in the treatment of post-operative pump failure following coronary revascularization.
Similar articles
-
Combined treatment of coenzyme Q10 and aprotinin with intraaortic balloon pumping following aorto-coronary bypass surgery.Jpn J Surg. 1984 Mar;14(2):97-103. doi: 10.1007/BF02469798. Jpn J Surg. 1984. PMID: 6205203
-
Prophylactic intra-aortic balloon pump in high-risk patients undergoing coronary artery bypass grafting: a propensity score analysis.Interact Cardiovasc Thorac Surg. 2009 Aug;9(2):291-4. doi: 10.1510/icvts.2008.196105. Epub 2009 Apr 9. Interact Cardiovasc Thorac Surg. 2009. PMID: 19359281
-
The effect of preoperative intra-aortic balloon pump support in high risk patients requiring myocardial revascularization.J Cardiovasc Surg (Torino). 1997 Aug;38(4):397-402. J Cardiovasc Surg (Torino). 1997. PMID: 9267351
-
Prophylactic intra-aortic balloon pump in high-risk patients undergoing coronary artery bypass surgery: a meta-analysis of randomized controlled trials.Coron Artery Dis. 2012 Nov;23(7):480-6. doi: 10.1097/MCA.0b013e328358784d. Coron Artery Dis. 2012. PMID: 22954753 Review.
-
Preoperative intra-aortic balloon pump use in high-risk patients prior to coronary artery bypass graft surgery decreases the risk for morbidity and mortality-A meta-analysis of 9,212 patients.J Card Surg. 2017 Mar;32(3):177-185. doi: 10.1111/jocs.13114. J Card Surg. 2017. PMID: 28247473 Review.
References
Publication types
MeSH terms
Substances
LinkOut - more resources