Effect of saliva contamination on the shear bond strength of a new self-etch adhesive system to dentin
- PMID: 24554857
- PMCID: PMC3915382
- DOI: 10.4103/0972-0707.124124
Effect of saliva contamination on the shear bond strength of a new self-etch adhesive system to dentin
Abstract
Aims and objectives: To evaluate the effect of saliva contamination on the shear bond strength of a new two-step self-etch adhesive (P90 system adhesive) to dentin and to determine the effect of contaminant removing treatments on the recovery of bond strengths.
Materials and methods: The buccal surfaces of 40 human premolars were ground to expose dentin. The specimens were randomly divided into four groups. Group 1 is uncontaminated and serves as the control group. Further groups were divided based on the step in the bonding sequence when the contamination had occurred as follows: Group 2 (primer, saliva contamination, rinse and dry), group 3 (after procedure of group 2, reapplication of primer), and group 4 (after procedure like in control group, saliva contamination, rinse and dry). Filtek P90 composite resin cylinders of 3 mm diameter and 3 mm length were fabricated on the surfaces. Shear bond strength testing was done in an Instron Universal Testing Machine and the data were subjected to one-way analysis of variance (ANOVA) and Student's t-test.
Results: With P90 system adhesive, group 2 and group 4 showed lower shear bond strength than group 1 (control) and group 3 (P < 0.05).
Conclusion: Saliva contamination significantly decreased the shear bond strength of the adhesive to dentin.
Keywords: Adhesion; contamination; self-etch primer; shear bond strength.
Conflict of interest statement
Figures
References
-
- Hitmi L, Attal JP, Degrange M. Influence of time point of salivary contamination on dentin shear bond strength of 3 dentin adhesive systems. J Adhes Dent. 1999;1:219–32. - PubMed
-
- Mojon P, Kaltio R, Feduik D, Hawbolt EB, MacEntee MI. Short term contamination of luting cements by water and saliva. Dent Mater. 1996;12:83–7. - PubMed
-
- Yoo HM, Oh TS, Pereira PN. Effect of saliva contamination on the micro shear bond strength of one step-etching Adhesive Systems to Dentin. Oper Dent. 2006;31:127–34. - PubMed
-
- Hormati AA, Fuller JL, Denehy GE. Effects of contamination and mechanical disturbance on the quality of acid-etched enamel. J Am Dent Assoc. 1980;100:34–8. - PubMed
-
- EL-Kalla IH, Garcia-Godoy F. Saliva contamination and bond strength of single-bottle adhesives to enamel and dentin. Am J Dent. 1997;10:83–7. - PubMed