3D finite element analysis of immediate loading of single wide versus double implants for replacing mandibular molar
- PMID: 24554890
- PMCID: PMC3917210
- DOI: 10.4103/0972-124X.124504
3D finite element analysis of immediate loading of single wide versus double implants for replacing mandibular molar
Abstract
Purpose: The purpose of this finite element study was to compare the stresses, strains, and displacements of double versus single implant in immediate loading for replacing mandibular molar.
Materials and methods: Two 3D FEM (finite element method) models were made to simulate implant designs. The first model used 5-mm-wide diameter implant to support a single molar crown. The second model used 3.75-3.75 double implant design. Anisotropic properties were assigned to bone model. Each model was analyzed with single force magnitude (100 N) in vertical axis.
Results: This FEM study suggested that micromotion can be controlled better for double implants compared to single wide-diameter implants. The Von Mises stress for double implant showed 74.44% stress reduction compared to that of 5-mm implant. The Von Mises elastic strain was reduced by 61% for double implant compared to 5-mm implant.
Conclusion: Within the limitations of the study, when the mesiodistal space for artificial tooth is more than 12.5 mm, under immediate loading, the double implant support should be considered.
Keywords: Dentistry; finite element analysis; stress analysis.
Conflict of interest statement
Figures
References
-
- Zarb GA, Schmitt A. The longitudinal clinical effectiveness of osseointegrated dental implants: The Toronto study. Part I: Surgical results. J Prosthet Dent. 1990;63:451–7. - PubMed
-
- Haas R, Mensdorff-Pouilly N, Mailath G, Watzek G. Branemark single tooth implants: A preliminary report of 76 implants. J Prosthet Dent. 1995;73:274–9. - PubMed
-
- Aparicio C, Orozco P. Use of 5-mm diameter implants: Periotest values related to a clinical and radiographic evaluation. Clin Oral Implants Res. 1998;9:398–406. - PubMed
-
- Seong WJ, Korioth TW, Hodges JS. Experimentally induced abutment strains in three types of single-molar implant restorations. J Prosthet Dent. 2000;84:318–26. - PubMed
-
- Balshi TJ, Hernandez RE, Pryszlak MC, Rangert B. A comparative study of one implant versus two replacing a single molar. Int J Oral Maxillofac Implants. 1996;11:372–8. - PubMed
LinkOut - more resources
Full Text Sources
Other Literature Sources