Web-based scoring of the dicentric assay, a collaborative biodosimetric scoring strategy for population triage in large scale radiation accidents
- PMID: 24557539
- DOI: 10.1007/s00411-014-0519-8
Web-based scoring of the dicentric assay, a collaborative biodosimetric scoring strategy for population triage in large scale radiation accidents
Abstract
In the case of a large scale radiation accident high throughput methods of biological dosimetry for population triage are needed to identify individuals requiring clinical treatment. The dicentric assay performed in web-based scoring mode may be a very suitable technique. Within the MULTIBIODOSE EU FP7 project a network is being established of 8 laboratories with expertise in dose estimations based on the dicentric assay. Here, the manual dicentric assay was tested in a web-based scoring mode. More than 23,000 high resolution images of metaphase spreads (only first mitosis) were captured by four laboratories and established as image galleries on the internet (cloud). The galleries included images of a complete dose effect curve (0-5.0 Gy) and three types of irradiation scenarios simulating acute whole body, partial body and protracted exposure. The blood samples had been irradiated in vitro with gamma rays at the University of Ghent, Belgium. Two laboratories provided image galleries from Fluorescence plus Giemsa stained slides (3 h colcemid) and the image galleries from the other two laboratories contained images from Giemsa stained preparations (24 h colcemid). Each of the 8 participating laboratories analysed 3 dose points of the dose effect curve (scoring 100 cells for each point) and 3 unknown dose points (50 cells) for each of the 3 simulated irradiation scenarios. At first all analyses were performed in a QuickScan Mode without scoring individual chromosomes, followed by conventional scoring (only complete cells, 46 centromeres). The calibration curves obtained using these two scoring methods were very similar, with no significant difference in the linear-quadratic curve coefficients. Analysis of variance showed a significant effect of dose on the yield of dicentrics, but no significant effect of the laboratories, different methods of slide preparation or different incubation times used for colcemid. The results obtained to date within the MULTIBIODOSE project by a network of 8 collaborating laboratories throughout Europe are very promising. The dicentric assay in the web based scoring mode as a high throughput scoring strategy is a useful application for biodosimetry in the case of a large scale radiation accident.
Similar articles
-
Automatic scoring of dicentric chromosomes as a tool in large scale radiation accidents.Mutat Res. 2013 Aug 30;756(1-2):174-83. doi: 10.1016/j.mrgentox.2013.05.013. Epub 2013 May 23. Mutat Res. 2013. PMID: 23707243
-
Validation of semi-automatic scoring of dicentric chromosomes after simulation of three different irradiation scenarios.Health Phys. 2014 Jun;106(6):764-71. doi: 10.1097/HP.0000000000000077. Health Phys. 2014. PMID: 24776911
-
RENEB Inter-Laboratory Comparison 2021: The Dicentric Chromosome Assay.Radiat Res. 2023 Jun 1;199(6):556-570. doi: 10.1667/RADE-22-00202.1. Radiat Res. 2023. PMID: 37018160
-
Operational guidance for radiation emergency response organisations in Europe for using biodosimetric tools developed in EU MULTIBIODOSE project.Radiat Prot Dosimetry. 2015 Apr;164(1-2):165-9. doi: 10.1093/rpd/ncu294. Epub 2014 Oct 1. Radiat Prot Dosimetry. 2015. PMID: 25274532 Review.
-
Cytogenetic biodosimetry: what it is and how we do it.Hong Kong Med J. 2013 Apr;19(2):168-73. Hong Kong Med J. 2013. PMID: 23535678 Review.
Cited by
-
Optimizing the Microscopy Time Schedule for Chromosomal Dosimetry of High-dose and Partial-body Irradiations.Genome Integr. 2017 Jan 23;8:3. doi: 10.4103/2041-9414.198908. eCollection 2017. Genome Integr. 2017. PMID: 28250910 Free PMC article.
-
Comparative gene expression analysis after exposure to 123I-iododeoxyuridine, γ- and α-radiation-potential biomarkers for the discrimination of radiation qualities.J Radiat Res. 2018 Jul 1;59(4):411-429. doi: 10.1093/jrr/rry038. J Radiat Res. 2018. PMID: 29800458 Free PMC article.
-
Radiation Biomarkers in Large Scale Human Health Effects Studies.J Pers Med. 2020 Oct 3;10(4):155. doi: 10.3390/jpm10040155. J Pers Med. 2020. PMID: 33023046 Free PMC article.
-
The Application of Imaging Flow Cytometry to High-Throughput Biodosimetry.Genome Integr. 2017 Jan 23;8:7. doi: 10.4103/2041-9414.198912. eCollection 2017. Genome Integr. 2017. PMID: 28250914 Free PMC article. Review.
-
Use of human lymphocyte G0 PCCs to detect intra- and inter-chromosomal aberrations for early radiation biodosimetry and retrospective assessment of radiation-induced effects.PLoS One. 2019 May 6;14(5):e0216081. doi: 10.1371/journal.pone.0216081. eCollection 2019. PLoS One. 2019. PMID: 31059552 Free PMC article.
References
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical