Guideline for determining the mean glandular dose according to DIN 6868-162 and threshold contrast visibility according to the quality assurance guideline for digital mammography systems
- PMID: 24557600
- DOI: 10.1055/s-0033-1356284
Guideline for determining the mean glandular dose according to DIN 6868-162 and threshold contrast visibility according to the quality assurance guideline for digital mammography systems
Abstract
As part of the physico-technical quality assurance of the German breast cancer screening program, the threshold contrast visibility and the average glandular dose of every digital mammography system have to fulfill the requirements of the "European guidelines for quality assurance in breast cancer screening and diagnosis" (4th Edition). To accomplish uniform measurements in all federal states of Germany, the physical board of the reference centers developed a special guideline in 2009. Due to recent changes in the guidelines and standards, a second version of the guideline was developed by the reference centers. This guideline describes the determination of the average glandular dose as well as the CDMAM image acquisition and the CDMAM image evaluation. The determination of the threshold contrast visibility can be performed visually or automatically. The determination of the average glandular dose is based on DIN 6868 - 162 and the threshold contrast visibility test is based on the German "Quality Assurance Guideline".
© Georg Thieme Verlag KG Stuttgart · New York.
Similar articles
-
[Guideline for the additional test positions according to the EPQC 4th Edition for Digital Mammography Systems].Rofo. 2009 Sep;181(9):845-50. doi: 10.1055/s-0028-1109610. Epub 2009 Aug 12. Rofo. 2009. PMID: 19676011 German.
-
[The quality of digital mammograms. Development and use of phantoms for optimal safety].Radiologe. 2005 Mar;45(3):278-85. doi: 10.1007/s00117-005-1180-7. Radiologe. 2005. PMID: 15747150 German.
-
Using a NPWE model observer to assess suitable image quality for a digital mammography quality assurance programme.Radiat Prot Dosimetry. 2010 Apr-May;139(1-3):459-62. doi: 10.1093/rpd/ncq010. Epub 2010 Apr 15. Radiat Prot Dosimetry. 2010. PMID: 20395413
-
Global quality control perspective for the physical and technical aspects of screen-film mammography--image quality and radiation dose.Radiat Prot Dosimetry. 2006;121(4):445-51. doi: 10.1093/rpd/ncl051. Epub 2006 May 18. Radiat Prot Dosimetry. 2006. PMID: 16709704 Review.
-
Implementing digital quality control in a breast center.J Am Coll Radiol. 2004 Nov;1(11):854-60. doi: 10.1016/j.jacr.2004.05.006. J Am Coll Radiol. 2004. PMID: 17411717 Review.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical
Research Materials