Determination of picogram quantities of chlortoluron in soil samples by luminol-chitosan chemiluminescence system
- PMID: 24566970
- DOI: 10.1007/s11356-014-2646-9
Determination of picogram quantities of chlortoluron in soil samples by luminol-chitosan chemiluminescence system
Abstract
Based on the enhancing effect of chitosan (CS) on luminol-dissolved oxygen chemiluminescence (CL) reaction, a flow injection (FI) luminol-CS CL system was established. It was found that the increase of CL intensity was proportional to the concentrations of CS ranging from 0.7 to 10.0 μmol l(-1). In the presence of chlortoluron (CTU), the CL intensity of luminol-CS system could be obviously inhibited and the decrements of CL intensity were linearly proportional to the logarithm of CTU concentrations ranging from 0.01 to 70.0 ng ml(-1), giving the limit of detection 3.0 pg ml(-1) (3σ). At a flow rate of 2.0 ml min(-1), the whole process including sampling and washing could be accomplished within 36 s, offering a sample throughput of 100 h(-1). The proposed FI-CL method was successfully applied to the determination of CTU in soil samples with recoveries ranging from 95.0 % to 105.3 % and the relative standard deviations (RSDs) of less than 4.0 %.
Similar articles
-
Assay of picogram level isocarbophos residue on tangerines and oranges with luminol-albumin chemiluminescence system.Food Chem. 2012 Dec 15;135(4):2549-53. doi: 10.1016/j.foodchem.2012.07.014. Epub 2012 Jul 14. Food Chem. 2012. PMID: 22980841
-
Pharmacokinetic of pseudoephedrine in rat serum with luminol-pepsin chemiluminescence system by flow injection analysis.Appl Biochem Biotechnol. 2015 Feb;175(4):1805-16. doi: 10.1007/s12010-014-1396-y. Epub 2014 Nov 27. Appl Biochem Biotechnol. 2015. PMID: 25427591
-
A flow injection chemiluminescence method for the determination of lincomycin in serum using a diperiodato-cuprate (III)-luminol system.Luminescence. 2011 Sep-Oct;26(5):313-8. doi: 10.1002/bio.1230. Epub 2010 Oct 23. Luminescence. 2011. PMID: 22021244
-
Peroxidase-catalyzed chemiluminescence system and its application in immunoassay.Talanta. 2018 Apr 1;180:260-270. doi: 10.1016/j.talanta.2017.12.024. Epub 2017 Dec 14. Talanta. 2018. PMID: 29332809 Review.
-
Luminol-based chemiluminescent signals: clinical and non-clinical application and future uses.Appl Biochem Biotechnol. 2014 May;173(2):333-55. doi: 10.1007/s12010-014-0850-1. Epub 2014 Apr 22. Appl Biochem Biotechnol. 2014. PMID: 24752935 Free PMC article. Review.
Cited by
-
Synthesis of fructose bound Fe(iii) integrated carbon dots as a robust turn-off detection sensor for chlortoluron.RSC Adv. 2023 Jun 6;13(25):17028-17037. doi: 10.1039/d3ra01430d. eCollection 2023 Jun 5. RSC Adv. 2023. PMID: 37293471 Free PMC article.
References
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Miscellaneous