Inferior suture anchor placement during arthroscopic Bankart repair: influence of portal placement and curved drill guide
- PMID: 24576744
- DOI: 10.1177/0363546514523722
Inferior suture anchor placement during arthroscopic Bankart repair: influence of portal placement and curved drill guide
Abstract
Background: During arthroscopic Bankart repair, inferior anchor placement is critical to a successful outcome. Low anterior anchors may be placed with a standard straight guide via midglenoid portal, with a straight guide with trans-subscapularis placement, or with curved guide systems. Purpose/
Hypothesis: To evaluate glenoid suture anchor trajectory, position, and biomechanical performance as a function of portal location and insertion technique. It is hypothesized that a trans-subscapularis portal or curved guide will improve anchor position, decrease risk of opposite cortex breach, and confer improved biomechanical properties.
Study design: Controlled laboratory study.
Methods: Thirty cadaveric shoulders were randomized to 1 of 3 groups: straight guide, midglenoid portal (MG); straight guide, trans-subscapularis portal (TS); and curved guide, midglenoid portal (CG). Three BioRaptor PK 2.3-mm anchors were inserted arthroscopically, with an anchor placed at 3, 5, and 7 o'clock. Specimens were dissected with any anchor perforation of the opposite cortex noted. An "en face" image was used to evaluate actual anchor position on a clockface scale. Each suture anchor underwent cyclic loading (10-60 N, 250 cycles), followed by a load-to-failure test (12.5 mm/s). Fisher exact test and mixed effects regression modeling were used to compare outcomes among groups.
Results: Anchor placement deviated from the desired position by 9.9° ± 11.4° in MG specimens, 11.1° ± 13.8° in TS, and 13.1° ± 14.5° in CG. After dissection, opposite cortex perforation at 5 o'clock occurred in 50% of MG anchors, 0% of TS, and 40% of CG. Of the 90 anchors tested, 17 (19%) failed during cyclic loading, with a similar failure rate across groups (P = .816). The maximum load was significantly higher for the 3-o'clock anchors when compared with the 5-o'clock anchors, regardless of portal or guide (P = .021). For the 5-o'clock position, there were significantly fewer "out" anchors in the TS group versus the CG or MG group (P = .038). There was no statistically significant difference in maximum load among groups at 5 o'clock.
Conclusion: Accuracy in suture anchor placement during arthroscopic Bankart repair can vary depending on both portal used and desired position of anchor. The results of the current study indicate that there was no difference in ultimate load to failure among anchors inserted via a midglenoid straight guide, midglenoid curved guide, or percutaneous trans-subscapularis approach. However, midglenoid portal anchors drilled with a straight or curved guide and placed at the 5-o'clock position had significant increased risk of opposite cortex perforation compared with trans-subscapularis percutaneous insertion, with no apparent biomechanical detriment.
Clinical relevance: The findings from this study will facilitate improved understanding of risks and benefits of several techniques for arthroscopic shoulder instability treatment with regard to suture anchor fixation.
Keywords: biomechanical; curved guide; glenoid portal; instability; percutaneous.
Similar articles
-
Inferior anchor cortical perforation with arthroscopic Bankart repair: a cadaveric study.Arthroscopy. 2013 Jan;29(1):31-6. doi: 10.1016/j.arthro.2012.08.013. Arthroscopy. 2013. PMID: 23276411
-
Safety of Hip Anchor Insertion From the Midanterior and Distal Anterolateral Portals With a Straight Drill Guide: A Cadaveric Study.Am J Sports Med. 2017 Mar;45(3):627-635. doi: 10.1177/0363546516673836. Epub 2016 Dec 7. Am J Sports Med. 2017. PMID: 27927616
-
Trans-subscapularis portal versus low-anterior portal for low anchor placement on the inferior glenoid fossa: a cadaveric shoulder study with computed tomographic analysis.Arthroscopy. 2015 Feb;31(2):209-14. doi: 10.1016/j.arthro.2014.08.009. Epub 2014 Sep 30. Arthroscopy. 2015. PMID: 25281478
-
What Makes Suture Anchor Use Safe in Hip Arthroscopy? A Systematic Review of Techniques and Safety Profile.Arthroscopy. 2019 Apr;35(4):1280-1293.e1. doi: 10.1016/j.arthro.2018.10.118. Epub 2019 Mar 14. Arthroscopy. 2019. PMID: 30878332
-
[Arthroscopic stabilization of the shoulder with suture anchors with special reference to the deep anterior-inferior portal (5.30 o'clock)].Oper Orthop Traumatol. 2007 Jun;19(2):133-54. doi: 10.1007/s00064-007-1199-1. Oper Orthop Traumatol. 2007. PMID: 17530195 Review. German.
Cited by
-
Comparison of suture anchor penetration rate between navigation-assisted and traditional shoulder arthroscopic capsulolabral repair.PLoS One. 2022 May 5;17(5):e0267943. doi: 10.1371/journal.pone.0267943. eCollection 2022. PLoS One. 2022. PMID: 35511770 Free PMC article. Clinical Trial.
-
[Research progress of surgical treatment for anterior shoulder dislocation and combined injuries].Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi. 2019 Jun 15;33(6):768-773. doi: 10.7507/1002-1892.201901021. Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi. 2019. PMID: 31198008 Free PMC article. Review. Chinese.
-
[Arthroscopic soft tissue stabilization of posttraumatic anterior shoulder instability : Techniques, limitations and long-term results].Unfallchirurg. 2018 Feb;121(2):108-116. doi: 10.1007/s00113-017-0438-7. Unfallchirurg. 2018. PMID: 29134236 Review. German.
-
Inter-surgeon variability in the identification of clock face landmarks when placing suture anchors in arthroscopic Bankart repair.Shoulder Elbow. 2019 Dec;11(6):419-423. doi: 10.1177/1758573218797964. Epub 2018 Sep 20. Shoulder Elbow. 2019. PMID: 32269601 Free PMC article.
-
Using a Posterolateral Portal to Pass and Tie the Suture of the Inferior Anchor During Arthroscopic Bankart Repair.Arthrosc Tech. 2016 Dec 26;5(6):e1467-e1470. doi: 10.1016/j.eats.2016.08.023. eCollection 2016 Dec. Arthrosc Tech. 2016. PMID: 28560145 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Research Materials