Provider acceptability of Sayana® Press: results from community health workers and clinic-based providers in Uganda and Senegal
- PMID: 24576792
- DOI: 10.1016/j.contraception.2014.01.009
Provider acceptability of Sayana® Press: results from community health workers and clinic-based providers in Uganda and Senegal
Abstract
Background: Sayana® Press (SP), a subcutaneous formulation of depot medroxyprogesterone acetate (DMPA) in Uniject™, has potential to be a valuable innovation in family planning (FP) because it may overcome logistic and safety challenges in delivering intramuscular DMPA (DMPA IM). However, SP's acceptability is unknown. We measured acceptability of SP among clinic-based providers (Senegal only) and community health workers.
Study design: This open-label observational study was conducted in clinics in three districts in Senegal and community-based services in two districts in Uganda. Providers administered SP to clients seeking reinjection of DMPA IM. We conducted in-depth interviews with 86 providers (52 in Senegal, 34 in Uganda) to assess their experiences providing SP to clients.
Results: Almost all providers (84/86; 98%) preferred SP over DMPA IM. The main reason Uganda providers preferred SP was the prefilled/all-in-one design made preparation and administration easier and faster. Some providers thought the SP all-in-one feature may decrease stock outs (DMPA IM requires syringe and vial). Providers also felt clients preferred the shorter SP needle because it is less intimidating and less painful. Similarly, the main reasons Senegal providers preferred SP were its characteristics (prefilled/all-in-one) and client preference (especially less pain). They also saw a potential to increase access to FP, especially through community-based distribution. Providers from both countries reported SP introduction would be enhanced through client counseling and community engagement. Providers also said SP must be accessible, affordable and in stock.
Conclusion: Almost all providers preferred SP over DMPA IM. Provider recommendations should be considered during SP introduction planning.
Implications: We found that SP was acceptable to both clinic-based FP providers and community health workers. Providers' positive attitudes towards SP may facilitate introduction and uptake of this method.
Trial registration: ClinicalTrials.gov NCT01667276.
Keywords: Community health worker; Contraception; Depot medroxyprogesterone acetate (DMPA); Subcutaneous injection.
Copyright © 2014 Elsevier Inc. All rights reserved.
Similar articles
-
Observational study of the acceptability of Sayana® Press among intramuscular DMPA users in Uganda and Senegal.Contraception. 2014 May;89(5):361-7. doi: 10.1016/j.contraception.2014.01.022. Epub 2014 Feb 6. Contraception. 2014. PMID: 24631328
-
Operational assessments of Sayana® Press provision in Senegal and Uganda.Contraception. 2014 May;89(5):374-8. doi: 10.1016/j.contraception.2014.01.005. Epub 2014 Jan 18. Contraception. 2014. PMID: 24565737
-
Preference for Sayana® Press versus intramuscular Depo-Provera among HIV-positive women in Rakai, Uganda: a randomized crossover trial.Contraception. 2014 May;89(5):385-95. doi: 10.1016/j.contraception.2013.11.008. Epub 2013 Nov 15. Contraception. 2014. PMID: 24332432 Clinical Trial.
-
Home-based administration of Sayana® Press: review and assessment of needs in low-resource settings.Contraception. 2014 May;89(5):344-51. doi: 10.1016/j.contraception.2014.03.003. Epub 2014 Mar 12. Contraception. 2014. PMID: 24813924 Review.
-
Injectable contraception: emerging evidence on subcutaneous self-administration.Curr Opin Obstet Gynecol. 2019 Dec;31(6):464-470. doi: 10.1097/GCO.0000000000000574. Curr Opin Obstet Gynecol. 2019. PMID: 31567445 Review.
Cited by
-
Acceptability of the distribution of DMPA-SC by community health workers among acceptors in the rural province of Lualaba in the Democratic Republic of the Congo: a pilot study.Contraception. 2018 Nov;98(5):454-459. doi: 10.1016/j.contraception.2018.08.004. Epub 2018 Aug 14. Contraception. 2018. PMID: 30118683 Free PMC article.
-
Introduction of Community-Based Provision of Subcutaneous Depot Medroxyprogesterone Acetate (DMPA-SC) in Benin: Programmatic Results.Glob Health Sci Pract. 2019 Jun 27;7(2):228-239. doi: 10.9745/GHSP-D-19-00002. Print 2019 Jun. Glob Health Sci Pract. 2019. PMID: 31171559 Free PMC article.
-
Adolescent and covert family planning users' experiences self-injecting contraception in Uganda and Malawi: implications for waste disposal of subcutaneous depot medroxyprogesterone acetate.Reprod Health. 2020 Aug 3;17(1):117. doi: 10.1186/s12978-020-00964-1. Reprod Health. 2020. PMID: 32746860 Free PMC article.
-
Characteristics associated with use of subcutaneous depot medroxyprogesterone acetate (DMPA-SC) in Burkina Faso, Democratic Republic of Congo, and Uganda.Contracept X. 2021 Jan 20;3:100055. doi: 10.1016/j.conx.2021.100055. eCollection 2021. Contracept X. 2021. PMID: 33554107 Free PMC article.
-
An observational study to test the acceptability and feasibility of using medical and nursing students to instruct clients in DMPA-SC self-injection at the community level in Kinshasa.Contraception. 2018 Nov;98(5):411-417. doi: 10.1016/j.contraception.2018.08.002. Epub 2018 Aug 16. Contraception. 2018. PMID: 30120925 Free PMC article.
Publication types
MeSH terms
Substances
Associated data
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical