Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2014 Jul;28(5):1280-5.
doi: 10.1016/j.avsg.2013.12.036. Epub 2014 Feb 27.

Intraarterial injection of indocyanine green for evaluation of peripheral blood circulation in patients with peripheral arterial disease

Affiliations
Comparative Study

Intraarterial injection of indocyanine green for evaluation of peripheral blood circulation in patients with peripheral arterial disease

Kimihiro Igari et al. Ann Vasc Surg. 2014 Jul.

Abstract

Background: To assess the peripheral blood flow of patients with peripheral arterial disease (PAD) by indocyanine green (ICG) arteriography (ICGA) with intraarterial injection of ICG and evaluate the efficacy of the ICGA tests.

Methods: This study was undertaken from a retrospective review of patients with PAD who underwent ICGA tests during digital subtraction angiography (DSA) between November 2012 and June 2013. We defined some ICGA parameters as the magnitude of intensity of ICG, the time to maximum intensity, and the time from fluorescence onset to half the maximum intensity (T1/2). The ICGA parameters were evaluated in 2 regions, named regions of interest (ROIs). ROI 1 was part of the dorsum of the foot from the Chopart joint to the Lisfranc joint. ROI 2 was in the distal region of the first metatarsal bone and compared with the ankle-brachial pressure index (ABI), ankle pressure, toe-brachial pressure index, and toe pressure.

Results: A total of 22 limbs in 16 patients with PAD underwent ICGA tests during DSA. The T1/2 on ROI 2 was the most correlated with the ABI (ρ=-0.622, P=0.003). A value of T1/2 for ROI 2>10 sec was significantly correlated with an ABI value of <0.7 (sensitivity: 0.85, specificity: 1.0).

Conclusions: By measuring the value of T1/2 in ROI 2, ICGA tests can be performed to assess the peripheral blood circulation during DSA. ICGA tests might help to promptly assess the peripheral blood flow during endovascular treatment procedures.