Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Review
. 2014 Jul;40(7):843-9.
doi: 10.1016/j.ejso.2014.02.228. Epub 2014 Feb 25.

Indocyanine green fluorescence-guided sentinel node biopsy: a meta-analysis on detection rate and diagnostic performance

Affiliations
Review

Indocyanine green fluorescence-guided sentinel node biopsy: a meta-analysis on detection rate and diagnostic performance

L Xiong et al. Eur J Surg Oncol. 2014 Jul.

Abstract

Background: Indocyanine green (ICG) fluorescence-guided sentinel node biopsy (SLNB) has been successfully employed in various kinds of tumors. Clinical results of previous studies on this technique are at different levels of evidence. This Meta-analysis was conducted to provide a more precise estimation on its clinical performance.

Methods: Eligible studies were identified from systematical PubMed and EMBASE searches; data were extracted. A Meta-analysis was performed to generate pooled detection rate, sensitivity, specificity, diagnostic odds ratio (DOR) and summary receiver operator characteristic curves.

Results: Fifteen published articles were included. Clinical data of 513 patients were obtained. The pooled detection rate, the pooled sensitivity, the pooled specificity, the pooled DOR and their 95% confidence intervals (95% CI) were 0.96 (0.91-0.99), 0.87 (0.79-0.92), 1.00 (0.99-1.00) and 150.13 (57.42-392.56), respectively. Significant heterogeneities existed among studies. Significant publication bias was found in detection rate. The concentration < 5 mg/ml subgroup and the injected volume ≥2 ml subgroup had higher DORs, sensitivities and detection rates than the concentration ≥ 5 mg/ml subgroup and the injected volume <2 ml subgroup, respectively.

Conclusion: Based on this Meta-analysis, this technique could be valued promising for detecting the presence of LN metastases. ICG injection with reduced concentration and larger volume may provide improved performance.

Keywords: Breast cancer; Colon cancer; Indocyanine green; Meta-analysis; Sentinel node biopsy.

PubMed Disclaimer

Comment in

LinkOut - more resources