Diagnostic accuracy of Xpert MTB/RIF for extrapulmonary tuberculosis specimens: establishing a laboratory testing algorithm for South Africa
- PMID: 24622091
- PMCID: PMC4042800
- DOI: 10.1128/JCM.03553-13
Diagnostic accuracy of Xpert MTB/RIF for extrapulmonary tuberculosis specimens: establishing a laboratory testing algorithm for South Africa
Abstract
South Africa implemented Xpert MTB/RIF as the initial diagnostic test for pulmonary tuberculosis (TB). Xpert MTB/RIF's accuracy for diagnosing extrapulmonary tuberculosis (EPTB) was investigated. EPTB specimens (n = 7,916) from hospitalized patients received over a 6-month period at a high-throughput TB referral laboratory in Johannesburg were investigated. Large-volume specimens were centrifuged, tissue biopsy specimens homogenized, and all specimens checked for growth of contaminating bacteria on blood agar. Contaminated samples received NALC-NaOH (N-acetyl-l-cysteine-sodium hydroxide) decontamination prior to liquid culture. Residual specimens (volumes > 1 ml) after inoculation of culture (n = 1,175) were tested using the Xpert MTB/RIF sputum protocol. Using culture as the reference, Xpert MTB/RIF's overall sensitivity was 59% (95% confidence interval [95% CI], 53% to 65%) and specificity was 92% (CI, 90% to 94%), with the highest sensitivities of 91% (95% CI, 78% to 97%) for pus, 80% (95% CI, 56% to 94%) for lymph node aspirates, and 51% (95% CI, 44% to 58%) for fluids (ascitic, 59%; pleural, 47%). A difference in sensitivities was noticed between specimens classified as having a thick (87% [95% CI, 76% to 94%]) versus clear (watery) (48% [95% CI, 36% to 61%]) appearance. This was unchanged with traces of blood (52% [95% CI, 44% to 60%]) or precentrifugation (57% [95% CI, 28% to 82%]) among clear specimens. Xpert MTB/RIF generated an additional 124 specimen results that were contaminated by Mycobacterial Growth Indicator Tubes (MGIT; 10.5%) and diagnosed rifampin (RIF) resistance earlier (9.6% [25/260]). Xpert MTB/RIF's performance on EPTB specimens provides very promising results and should be considered for incorporation into national TB guidelines. Xpert MTB/RIF is less affected by contaminating bacteria and reduces laboratory labor and diagnostic delay compared to traditional methods.
Copyright © 2014, American Society for Microbiology. All Rights Reserved.
References
-
- Boehme CC, Nabeta P, Hillemann D, Nicol MP, Shenai S, Krapp F, Allen J, Tahirli R, Blakemore R, Rustomjee R, Milovic A, Jones M, O'Brien SM, Persing DH, Ruesch-Gerdes S, Gotuzzo E, Rodrigues C, Alland D, Perkins MD. 2010. Rapid molecular detection of tuberculosis and rifampin resistance. N. Engl. J. Med. 363:1005–1015. 10.1056/NEJMoa0907847 - DOI - PMC - PubMed
-
- Tortoli E, Russo C, Piersimoni C, Mazzola E, Dal Monte P, Pascarella M, Borroni E, Mondo A, Piana F, Scarparo C, Coltella L, Lombardi G, Cirillo DM. 2012. Clinical validation of Xpert MTB/RIF for the diagnosis of extrapulmonary tuberculosis. Eur. Respir. J. 40:442–447. 10.1183/09031936.00176311 - DOI - PubMed
Publication types
MeSH terms
Substances
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical