A novel technique for accurate Poller (blocking) screw placement
- PMID: 24629702
- DOI: 10.1016/j.injury.2014.02.029
A novel technique for accurate Poller (blocking) screw placement
Abstract
Achieving good results with intramedullary nailing of oblique long bone fractures at the metaphyseal-diaphyseal junction can be difficult. There is a strong tendency for axial displacement and an association with characteristic malalignment of the short fragment. Poller or blocking screws have been shown to be effective in aiding fracture reduction. While several papers describe methods for screw placement, these are confusing to understand, difficult to follow in clinical practice and not always applicable. Here we describe a new, simple, reproducible and easy to use method for ensuring accurate Poller screw placement, in order to maximise the benefits of their use and achieve good overall results.
Keywords: Blocking screw; Intramedullary nail; Poller screw.
Copyright © 2014 Elsevier Ltd. All rights reserved.
Comment in
-
A more practical way to place a correct Poller (blocking) screw.Injury. 2016 Feb;47(2):510-1. doi: 10.1016/j.injury.2015.11.036. Epub 2015 Nov 28. Injury. 2016. PMID: 26671011 No abstract available.