Marking wire placement for improved accuracy in thoracic spinal surgery

Affiliations

Marking wire placement for improved accuracy in thoracic spinal surgery

Sebastian A Ahmadi et al. Clin Neurol Neurosurg. 2014 Apr.

Abstract

Objective: To present an innovative approach that does not rely on intraoperative X-ray imaging for identifying thoracic target levels and critically appraise its value in reducing the risk of wrong-level surgery and radiation exposure.

Methods: 96 patients admitted for surgery of the thoracic spine were prospectively enrolled, undergoing a total of 99 marking wire placements. Preoperatively a flexible marking wire derived from breast cancer surgery was inserted with computed tomography (CT) guidance at the site of interest--the wire was then used as an intraoperative guidance tool.

Results: Wire placement was considered successful in 96 cases (97%). Most common pathologies were tumors (62.5%) and degenerative disorders (16.7%). Effective doses from CT imaging were significantly higher for wire placements in the upper third of the thoracic spine compared to the lower two thirds (p = 0.015). Radiation exposure to operating room personnel could be reduced by more than 90% in all non-instrumented cases. No adverse reactions were observed, one patient (1.04%) underwent surgical revision due to an epifascial empyema. No wires had to be removed due to lack of patient compliance or infection.

Conclusions: This is a safe and practical approach to identify the level of interest in thoracic spinal surgery employing a marking wire. Its application merits consideration in any spinal case where X-ray localization could prove unsafe, particularly in cases lacking bony pathologies such as intradural tumors.

Keywords: Localization; Marking wire; Radiation exposure; Spine; Thoracic; Wrong-level surgery.