Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2014 Jun;46(6):791-9.
doi: 10.1016/j.jemermed.2013.12.002. Epub 2014 Mar 11.

Emergency department variation in utilization and diagnostic yield of advanced radiography in diagnosis of pulmonary embolus

Affiliations

Emergency department variation in utilization and diagnostic yield of advanced radiography in diagnosis of pulmonary embolus

Dana R Kindermann et al. J Emerg Med. 2014 Jun.

Abstract

Background: There is growing pressure to measure and reduce unnecessary imaging in the emergency department.

Objective: We study provider and hospital variation in utilization and diagnostic yield for advanced radiography in diagnosis of pulmonary embolism (PE) and to assess patient- and provider-level factors associated with diagnostic yield.

Methods: Retrospective chart review of all adult patients presenting to four hospitals from January 2006 through December 2009 who had a computed tomography or ventilation/perfusion scan to evaluate for PE. Demographic data on the providers ordering the scans were collected. Diagnostic yield (positive scans/total scans ordered) was calculated at the hospital and provider level. The study was not designed to assess appropriateness of imaging.

Results: There was significant variation in utilization and diagnostic yield at the hospital level (chi-squared, p < 0.05). Diagnostic yield ranged from 4.2% to 8.2%; after adjusting for patient- and provider-level factors; the two hospitals with an emergency medicine residency training program had higher diagnostic yields (odds ratio [OR] 2.0, 95% confidence interval [CI] 1.6-2.5 and OR 1.9, 95% CI 1.5-2.4). There was no significant variation in diagnostic yield among the 90 providers after adjusting for patient, hospital, and provider characteristics. Providers with < 10 years of experience had lower odds of diagnosing a PE than more experienced graduates (OR 0.8, 95% CI 0.6-0.9).

Conclusions: Although we found significant variation in utilization of advanced radiography for PE and diagnostic yield at the hospital level, there was no significant variation at the provider level after adjusting for patient-, hospital-, and provider-level factors.

Keywords: diagnostic yield; imaging; resource utilization.