Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2014 Mar;100(3):147-51.
doi: 10.17992/lbl.2014.03.536.

[Fetal loss after amniocentesis and chorionic villus sampling in Iceland]

[Article in Icelandic]
Free article
Comparative Study

[Fetal loss after amniocentesis and chorionic villus sampling in Iceland]

[Article in Icelandic]
Kristin Rut Haraldsdottir et al. Laeknabladid. 2014 Mar.
Free article

Abstract

Introduction: Amniocentesis and chorionic villus sampling (CVS) are methods for fetal chromosomal diagnosis. Pregnant women aged ≥35 years have been offered amniocentesis in Iceland for over 35 years. The main testing indication was maternal age until 1998, when universal early screening was introduced. We examined outcome and fetal loss following amniocentesis and CVS in singleton and twin pregnancies, age distribution changes, reasons for the procedures and fetal karyotype diagnoses.

Material and methods: Retrospective quantitative study on women who had amniocentesis and CVS (n=2323) in the Prenatal Diagnosis Unit at Landspitali University Hospital during 1998-2007. Unit files and individual case and maternity records were used to retrieve information on the indications and on maternal age, type of procedure, outome of pregnancy, and the fetal karyotype.

Results: The number of procedures was substantially reduced from over 500 to just over 100 per year, with a proportional shift to CVS. Procedure-related fetal loss was 22/2323 (0.9%), with no significant difference between amniocentesis (0.8%) and CVS (1.3%). The difference decreased in the latter half of the study period to 0.7% and 0.8%, respectively. Age-related reasons decreased from 81.2% to 30.8%.

Conclusion: The fetal loss incidence rates indicated that amniocentesis and CVS have the same safety level as elsewhere. Complications were uncommon. With CVS fetal screening was moved to an earlier time in pregnancy. Early screening has changed the maternal age profile and is available to all women on request. The information obtained can be used to improve service information.

PubMed Disclaimer

LinkOut - more resources