Mapping and ablating stable sources for atrial fibrillation: summary of the literature on Focal Impulse and Rotor Modulation (FIRM)
- PMID: 24647673
- DOI: 10.1007/s10840-014-9889-8
Mapping and ablating stable sources for atrial fibrillation: summary of the literature on Focal Impulse and Rotor Modulation (FIRM)
Abstract
Atrial fibrillation (AF) is the most common sustained arrhythmia and the most common indication for catheter ablation. However, despite substantial technical advances in mapping and energy delivery, ablation outcomes remain suboptimal. A major limitation to AF ablation is that the areas targeted for ablation are rarely of proven mechanistic importance, in sharp contrast to other arrhythmias in which ablation targets demonstrated mechanisms in each patient. Focal impulse and rotor modulation (FIRM) is a new approach to demonstrate the mechanisms that sustain AF ("substrates") in each patient that can be used to guide ablation then confirm elimination of each mechanism. FIRM mapping reveals that AF is sustained by 2-3 rotors and focal sources, with a greater number in patients with persistent than paroxysmal AF, lying within spatially reproducible 2.2 ± 1.4-cm(2) areas in diverse locations. This temporospatial reproducibility, now confirmed by several groups using various methods, changes the concepts regarding AF-sustaining mechanisms, enabling localized rather than widespread ablation. Mechanistically, the role of rotors and focal sources in sustaining AF has been demonstrated by the acute and chronic success of source (FIRM) ablation alone. Clinically, adding FIRM to conventional ablation substantially improves arrhythmia freedom compared with conventional ablation alone, and ongoing randomized trials are comparing FIRM-ablation with and without conventional ablation to conventional ablation alone. In conclusion, ablation of patient-specific AF-sustaining mechanisms (substrates), as exemplified by FIRM, may be central to substantially improving AF ablation outcomes.
Similar articles
-
Ablation of rotor and focal sources reduces late recurrence of atrial fibrillation compared with trigger ablation alone: extended follow-up of the CONFIRM trial (Conventional Ablation for Atrial Fibrillation With or Without Focal Impulse and Rotor Modulation).J Am Coll Cardiol. 2014 May 6;63(17):1761-8. doi: 10.1016/j.jacc.2014.02.543. Epub 2014 Mar 13. J Am Coll Cardiol. 2014. PMID: 24632280 Free PMC article. Clinical Trial.
-
Treatment of atrial fibrillation by the ablation of localized sources: CONFIRM (Conventional Ablation for Atrial Fibrillation With or Without Focal Impulse and Rotor Modulation) trial.J Am Coll Cardiol. 2012 Aug 14;60(7):628-36. doi: 10.1016/j.jacc.2012.05.022. Epub 2012 Jul 18. J Am Coll Cardiol. 2012. PMID: 22818076 Free PMC article. Clinical Trial.
-
Direct or coincidental elimination of stable rotors or focal sources may explain successful atrial fibrillation ablation: on-treatment analysis of the CONFIRM trial (Conventional ablation for AF with or without focal impulse and rotor modulation).J Am Coll Cardiol. 2013 Jul 9;62(2):138-147. doi: 10.1016/j.jacc.2013.03.021. Epub 2013 Apr 3. J Am Coll Cardiol. 2013. PMID: 23563126 Free PMC article. Clinical Trial.
-
Ablating Atrial Fibrillation: Customizing Lesion Sets Guided by Rotor Mapping.Methodist Debakey Cardiovasc J. 2015 Apr-Jun;11(2):76-81. doi: 10.14797/mdcj-11-2-76. Methodist Debakey Cardiovasc J. 2015. PMID: 26306123 Free PMC article. Review.
-
Rotors as drivers of atrial fibrillation and targets for ablation.Curr Cardiol Rep. 2014 Aug;16(8):509. doi: 10.1007/s11886-014-0509-0. Curr Cardiol Rep. 2014. PMID: 24950671 Free PMC article. Review.
Cited by
-
Cryoablation in persistent atrial fibrillation - a critical appraisal.Neth Heart J. 2016 Sep;24(9):498-507. doi: 10.1007/s12471-016-0858-y. Neth Heart J. 2016. PMID: 27294840 Free PMC article. Review.
-
Cryoballoon ablation results and complications in mid-term follow-up of patients with atrial fibrillation.ARYA Atheroscler. 2018 Nov;14(6):272-275. doi: 10.22122/arya.v14i6.1772. ARYA Atheroscler. 2018. PMID: 31143228 Free PMC article.
-
High-density mapping of the average complex interval helps localizing atrial fibrillation drivers and predicts catheter ablation outcomes.Front Cardiovasc Med. 2023 Aug 17;10:1145894. doi: 10.3389/fcvm.2023.1145894. eCollection 2023. Front Cardiovasc Med. 2023. PMID: 37663412 Free PMC article.
-
Repeat pulmonary vein isolation with or without FIRM-guided ablation for recurrent atrial fibrillation with pulmonary vein reconnection.J Cardiovasc Electrophysiol. 2020 May;31(5):1031-1037. doi: 10.1111/jce.14426. Epub 2020 Mar 9. J Cardiovasc Electrophysiol. 2020. PMID: 32115794 Free PMC article.
-
Ten-year outcome of intraoperative treatment of atrial fibrillation using radiofrequency ablation.Ther Clin Risk Manag. 2017 Sep 19;13:1233-1237. doi: 10.2147/TCRM.S136173. eCollection 2017. Ther Clin Risk Manag. 2017. PMID: 29033573 Free PMC article.
References
Publication types
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical