Bloodless surgery in a pediatric Jehovah's Witness
- PMID: 24649574
- PMCID: PMC4557499
Bloodless surgery in a pediatric Jehovah's Witness
Abstract
Pediatric cardiac surgery in Jehovah's Witness patients who refuse the use of blood products remains a challenge because of the extreme hemodilution caused by priming the circuit and subsequent cardiopulmonary bypass. We report our successful strategy for reducing the prime volume for a 2-year-old Jehovah's Witness patient who required open heart surgery. We modified our conventional bypass circuit requirements for this size child by incorporating a lower prime oxygenator and reducing the size of the venous line and circuit, which decreased the circuit prime volume. We managed to reduce our initial sanguineous prime volume from 315 to 210 mL. The prime was further reduced to 160 mL by minimizing circuit length at the field and with venous prime sequestration prebypass. The postbypass hematocrit was 31%. Bloodless pediatric cardiac surgery in Jehovah's Witness patients can be performed safely. Incorporating a lower prime oxygenator into a revised circuit alleviated the need for blood transfusion and allowed us to achieve our calculated flow rate of 2.6 L/min/m2 while maintaining a hematocrit of 31%.
Conflict of interest statement
The senior author has stated that the authors have reported no material, financial, or other relationship with any healthcare-related business or other entity whose products or services are discussed in this paper.
References
-
- Miyaji KA, Kohira SA, Miyamoto TA, et al. . Pediatric cardiac surgery without homologous blood transfusion, using a miniaturized bypass system in infants with lower body weight. J Thorac Surg. 2007;134:284–289. - PubMed
-
- Forest RJ, Groom RC, Quinn R, Donnelly J, Clark C.. Repair of hypoplastic left heart syndrome in a 4.25 kg Jehovah’s Witness. Perfusion. 2002;17:221–225. - PubMed
-
- Karimi MO, Florentino-Pineda IV, Weatherred TE, et al. . Blood conservation operations in pediatric cardiac patients: A paradigm shift of blood use. Ann Thorac Surg. 2013;95:962–967. - PubMed
-
- Nakanishi K, Shichijo T, Shinkawa Y, et al. . Usefulness of vacuum-assisted cardiopulmonary bypass circuit for pediatric open-heart surgery in reducing homologous blood transfusion. Eur J Cardiothorac Surg. 2001;20:233–238. - PubMed
-
- Utley JR, Stephens DB, Wachtel C, et al. . Effect of albumin and mannitol on organ blood flow, oxygen delivery, water content and renal function during hypothermic hemodilution cardiopulmonary bypass. Ann Thorac Surg. 1982;33:250–257. - PubMed