Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Controlled Clinical Trial
. 2014 Aug;49(8):518-23.
doi: 10.1097/RLI.0000000000000046.

Peripheral nerve perfusion by dynamic contrast-enhanced magnetic resonance imaging: demonstration of feasibility

Affiliations
Controlled Clinical Trial

Peripheral nerve perfusion by dynamic contrast-enhanced magnetic resonance imaging: demonstration of feasibility

Philipp Bäumer et al. Invest Radiol. 2014 Aug.

Abstract

Purpose: The aim of this study was to establish dynamic contrast-enhanced perfusion in peripheral nerves for determination of blood-nerve permeability (K) and nerve blood volume (NBV) in peripheral neuropathies as compared with healthy controls.

Methods: The study was approved by the institutional ethics committee, and written informed consent was obtained from all participants. Forty-three controls (24 women, 19 men; age, 48.7 ± 17.5 years) and 59 patients with peripheral neuropathy (28 women, 31 men; age, 52.7 ± 12.4 years) were examined by a standard protocol including a T1-weighted dynamic contrast-enhanced sequence (time of repetition/time of echo, 4.91/1.64; 10 slices; resolution 0.8 × 0.6 × 3.0 mm3). Time - signal intensity analysis was performed by normalizing to pre-bolus arrival and calculating the mean contrast uptake (MCU) for each patient. Further analyses were performed by customized software to calculate K trans and NBV. Statistical analysis included 2-sided Student's t tests of controls versus patients, receiver operating characteristic analysis, and subgroup analysis of patients according to etiologies of neuropathy.

Results: Time-signal intensity analysis showed significantly increased contrast uptake in patients as compared with controls (MCU, 1.29 ± 0.15 vs 1.18 ± 0.08; P < 0.001). This was caused mainly by an increase in K trans (0.046 ± 0.025 vs 0.026 ± 0.016 min(-1); P < 0.001) and less by an increase in NBV (3.9 ± 2.6 vs 3.0 ± 1.9 mL/100 mL; P = 0.12). This trend was true for all etiologies except entrapment neuropathies. Excluding these, receiver operating characteristic analysis found an area under the curve of 0.78 (95% confidence interval, 0.69-0.89) for MCU and 0.77 (95% confidence interval, 0.65-0.90) for K to discriminate neuropathy from control.

Conclusions: Dynamic contrast-enhanced perfusion is a feasible technique to assess K trans and NBV in peripheral nerves and may be used in future investigations on peripheral neuropathies.

PubMed Disclaimer

Publication types

MeSH terms

LinkOut - more resources