Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2014 Aug;35(6):1037-45.
doi: 10.1007/s00246-014-0895-5. Epub 2014 Mar 21.

Local reference levels and organ doses from pediatric cardiac interventional procedures

Affiliations

Local reference levels and organ doses from pediatric cardiac interventional procedures

S Barnaoui et al. Pediatr Cardiol. 2014 Aug.

Abstract

Interventional cardiology (IC) procedures can be responsible for relatively high radiation doses compared to conventional radiology especially for young patients. The aim of this study was to assess current exposure levels in a French reference centre of pediatric IC. Dosimetric data including dose area product (DAP), fluoroscopy time (FT) and number of cine frame (NF) were analysed taking into account patient weight. Doses to the lungs, esophagus, breast and thyroid were evaluated using anthropomorphic phantoms and thermoluminescent dosimeters. Finally, effective doses (E) were calculated using DAP and conversion factors calculated with PCXMC 2.0 software. 801 IC procedures performed between 2010 and 2011 were analysed. Large variations were observed for DAP, FT and NF values for a given procedure and a given weight group. The assessment of organ doses showed high levels of dose to the lungs and esophagus especially in new-born babies. For diagnostic procedures, E varied from 0.3 to 23 mSv with a mean value of 4.8 mSv and for therapeutic procedures, values ranged from 0.1 to 48.4 mSv with a mean value of 7.3 mSv. The highest values were recorded for angioplasty procedures (mean 13 mSv, range 0.6-48.4 mSv). The increasing use of IC in pediatric population stresses the need of setting up reference levels and keeping doses to children as low as possible.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Circulation. 2005 Jan 4;111(1):83-9 - PubMed
    1. Arch Pediatr. 2012 Jan;19(1):96-102 - PubMed
    1. Br J Radiol. 2009 Aug;82(981):748-55 - PubMed
    1. Br J Radiol. 2000 Feb;73(866):172-83 - PubMed
    1. Phys Med Biol. 2000 Oct;45(10):3095-107 - PubMed

Publication types

MeSH terms

LinkOut - more resources