Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2014 Jun;30(6):613-8.
doi: 10.1016/j.dental.2014.02.024. Epub 2014 Mar 19.

Effect of temperature on composite polymerization stress and degree of conversion

Affiliations

Effect of temperature on composite polymerization stress and degree of conversion

Fernanda C Calheiros et al. Dent Mater. 2014 Jun.

Abstract

Objective: To test the following hypotheses: (1) degree of conversion (DC) and polymerization stress (PS) increase with composite temperature (2) reduced light-exposure applied to pre-heated composites produces similar conversion as room temperature with decreased PS.

Methods: Composite specimens (diameter: 5mm, height: 2mm) were tested isothermally at 22°C (control), 40°C, and 60°C using light-exposures of 5 or 20s (control). DC was accessed 5min after light initiation by FTIR at the specimen bottom surface. Maximum and final PS were determined, also isothermally, for 5min on a universal testing machine. Non-isothermal stress was also measured with composite maintained at 22°C or 60°C, and irradiated for 20s at 30°C. Data were analyzed using two-way ANOVA/Tukey and Student's t-test (α=5%).

Results: Both DC and isothermal maximum stress increased with temperature (p<0.001) and exposure duration (p<0.001). Isothermal maximum/final stress (MPa) were 3.4±2.0b/3.4±2.0A (22°C), 3.7±1.5b/3.6±1.4A (40°C) and 5.1±2.0a/4.0±1.6A (60°C). Conversion values (%) were 39.2±7.1c (22°C), 50.0±5.4b (40°C) and 58.5±5.7a (60°C). The reduction of light exposure duration (from 20s to 5s) with pre-heated composite yielded the same or significantly higher conversion (%) than control (22°C, 20s/control: 45.4±1.8b, 40°C, 5s s: 45.1±0.5b, 60°C, 5s s: 53.7±2.7a, p<0.01). Non-Isothermal conditions showed significantly higher stress for 60°C than 22°C (in MPa, maximum: 4.7±0.5 and 3.7±0.4, final: 4.6±0.6 and 3.6±0.4, respectively).

Clinical significance: Increasing composite temperature allows for reduced exposure duration and lower polymerization stress (both maximum and final) while maintaining or increasing degree of conversion.

Keywords: Composite resin; Degree of conversion; Polymerization stress; Pre-heated composites.

PubMed Disclaimer

Substances

LinkOut - more resources